The DOI matches its Crossref record.
Turnover Numbers, Turnover Frequencies, and Overpotential in Molecular Catalysis of Electrochemical Reactions. Cyclic Voltammetry and Preparative-Scale Electrolysis
Abstract
The search for efficient catalysts to face modern energy challenges requires evaluation and comparison through reliable methods. Catalytic current efficiencies may be the combination of many factors besides the intrinsic chemical properties of the catalyst. Defining turnover number and turnover frequency (TOF) as reflecting these intrinsic chemical properties, it is shown that catalysts are not characterized by their TOF and their overpotential (η) as separate parameters but rather that the parameters are linked together by a definite relationship. The log TOF-η relationship can often be linearized, giving rise to a Tafel law, which allows the characterization of the catalyst by the value of the TOF at zero overpotential (TOF(0)). Foot-of-the-wave analysis of the cyclic voltammetric catalytic responses allows the determination of the TOF, log TOF-η relationship, and TOF(0), regardless of the side-phenomena that interfere at high current densities, preventing the expected catalytic current plateau from being reached. Strategies for optimized preparative-scale electrolyses may then be devised on these bases. The validity of this methodology is established on theoretical grounds and checked experimentally with examples taken from the catalytic reduction of CO(2) by iron(0) porphyrins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heterostructures for Electrochemical Hydrogen Evolution Reaction: A Review
Zhao, G., Rui, K., Dou, S. X., & Sun, W. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201803291 · Cited by 1,422
A Local Proton Source Enhances CO 2 Electroreduction to CO by a Molecular Fe Catalyst
Costentin, C., Drouet, S., Robert, M., & Savéant, J.-M. (2012) · Science · doi:10.1126/science.1224581 · Cited by 1,315
Self-citationImpedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Electrocatalytic reduction of carbon dioxide: opportunities with heterogeneous molecular catalysts
Sun, L., Reddu, V., Fisher, A. C., & Wang, X. (2020) · Energy & Environmental Science · doi:10.1039/c9ee03660a · Cited by 452
A Biomimetic Copper Water Oxidation Catalyst with Low Overpotential
Zhang, T., Wang, C., Liu, S., Wang, J.-L., & Lin, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja409267p · Cited by 389
Metadata
- Authors
- Costentin, C., Drouet, S., Robert, M., & Savéant, J.-M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-27
- Volume
- 134
- Issue
- 27
- Pages
- 11235-11242
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2332448579
- Cited by
- 849
- References
- 0
- FWCI
- 11.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Turnover Numbers, Turnover Frequencies, and Overpotential in Molecular Catalysis of Electrochemical Reactions. Cyclic Voltammetry and Preparative-Scale Electrolysis. https://app.cochat.ai/papers/10.1021/ja303560c
- The paper
- Costentin, C., Drouet, S., Robert, M., & Savéant, J.-M. (2012). Turnover Numbers, Turnover Frequencies, and Overpotential in Molecular Catalysis of Electrochemical Reactions. Cyclic Voltammetry and Preparative-Scale Electrolysis. Journal of the American Chemical Society. https://doi.org/10.1021/ja303560c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.