The DOI matches its Crossref record.
DNA Analysis by Application of Pt Nanoparticle Electrochemical Amplification with Single Label Response
Abstract
This study demonstrates a highly sensitive sensing scheme for the detection of low concentrations of DNA, in principle down to the single biomolecule level. The previously developed technique of electrochemical current amplification for detection of single nanoparticle (NP) collisions at an ultramicroelectrode (UME) has been employed to determine DNA. The Pt NP/Au UME/hydrazine oxidation reaction was employed, and individual NP collision events were monitored. The Pt NP was modified with a 20-base oligonucleotide with a C6 spacer thiol (detection probe), and the Au UME was modified with a 16-base oligonucleotide with a C6 spacer thiol (capture probe). The presence of a target oligonucleotide (31 base) that hybridized with both capture and detection probes brought a Pt NP on the electrode surface, where the resulting electrochemical oxidation of hydrazine resulted in a current response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanomaterials based electrochemical sensors for biomedical applications
Chen, A., & Chatterjee, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35518g · Cited by 956
Biogenic synthesis of nanoparticles: A review
Sharma, D., Kanchi, S., & Bisetty, K. (2019) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2015.11.002 · Cited by 948
Recent Advances in Biosensor Technology for Potential Applications – An Overview
Vigneshvar, S., Sudhakumari, C. C., Senthilkumaran, B., & Prakash, H. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00011 · Cited by 674
“Some of the advancement are seen in electrochemical sensors in combination with nanomaterials results in new types of biosensors (Kwon and Bard, 2012; Bandodkar and Wang, 2014).”
BackgroundMethodInfluentialSajid, M., Ilyas, M., Basheer, C., Tariq, M., Daud, M., Baig, N., & Shehzad, F. (2015) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-3994-1 · Cited by 447
Correlated Electrochemical and Optical Tracking of Discrete Collision Events
Fosdick, S. E., Anderson, M. J., Nettleton, E. G., & Crooks, R. M. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401864k · Cited by 166
Metadata
- Authors
- Kwon, S. J., & Bard, A. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-20
- Volume
- 134
- Issue
- 26
- Pages
- 10777-10779
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2060385735
- Cited by
- 199
- References
- 0
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DNA Analysis by Application of Pt Nanoparticle Electrochemical Amplification with Single Label Response. https://app.cochat.ai/papers/10.1021/ja304074f
- The paper
- Kwon, S. J., & Bard, A. J. (2012). DNA Analysis by Application of Pt Nanoparticle Electrochemical Amplification with Single Label Response. Journal of the American Chemical Society. https://doi.org/10.1021/ja304074f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.