The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly-Efficient Gating of Solid-State Nanochannels by DNA Supersandwich Structure Containing ATP Aptamers: A Nanofluidic IMPLICATION Logic Device
Abstract
Integrating biological components into artificial devices establishes an interface to understand and imitate the superior functionalities of the living systems. One challenge in developing biohybrid nanosystems mimicking the gating function of the biological ion channels is to enhance the gating efficiency of the man-made systems. Herein, we demonstrate a DNA supersandwich and ATP gated nanofluidic device that exhibits high ON-OFF ratios (up to 10(6)) and a perfect electric seal at its closed state (~GΩ). The ON-OFF ratio is distinctly higher than existing chemically modified nanofluidic gating systems. The gigaohm seal is comparable with that required in ion channel electrophysiological recording and some lipid bilayer-coated nanopore sensors. The gating function is implemented by self-assembling DNA supersandwich structures into solid-state nanochannels (open-to-closed) and their disassembly through ATP-DNA binding interactions (closed-to-open). On the basis of the reversible and all-or-none electrochemical switching properties, we further achieve the IMPLICATION logic operations within the nanofluidic structures. The present biohybrid nanofluidic device translates molecular events into electrical signals and indicates a built-in signal amplification mechanism for future nanofluidic biosensing and modular DNA computing on solid-state substrates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
‘Memristive’ switches enable ‘stateful’ logic operations via material implication
Borghetti, J., Snider, G. S., Kuekes, P. J., Yang, J. J., Stewart, D. R., & Williams, R. S. (2010) · Nature · doi:10.1038/nature08940 · Cited by 1,929
Cited by
High-Performance Ionic Diode Membrane for Salinity Gradient Power Generation
Gao, J., Guo, W., Feng, D., Wang, H., Zhao, D., & Jiang, L. (2014) · Journal of the American Chemical Society · doi:10.1021/ja503692z · Cited by 615
Self-citationBioinspired Artificial Single Ion Pump
Zhang, H., Hou, X., Zeng, L., Yang, F., Li, L., Yan, D., Tian, Y., & Jiang, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4037669 · Cited by 286
Self-citationSong, Y., Li, Y., Xu, Q., & Liu, Z. (2016) · International Journal of Nanomedicine · doi:10.2147/ijn.s117495 · Cited by 258
Metadata
- Authors
- Jiang, Y., Liu, N., Guo, W., Xia, F., & Jiang, L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-06
- Volume
- 134
- Issue
- 37
- Pages
- 15395-15401
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2314017885
- Cited by
- 227
- References
- 1
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.