The DOI matches its Crossref record.
Rational Design of Highly Sensitive Fluorescence Probes for Protease and Glycosidase Based on Precisely Controlled Spirocyclization
Abstract
We have synthesized and evaluated a series of hydroxymethyl rhodamine derivatives and found an intriguing difference of intramolecular spirocyclization behavior: the acetylated derivative of hydroxymethyl rhodamine green (Ac-HMRG) exists as a closed spirocyclic structure in aqueous solution at physiological pH, whereas HMRG itself takes an open nonspirocyclic structure. Ac-HMRG is colorless and nonfluorescent, whereas HMRG is strongly fluorescent. On the basis of these findings, we have developed a general design strategy to obtain highly sensitive fluorescence probes for proteases and glycosidases, by replacing the acetyl group of Ac-HMRG with a substrate moiety of the target enzyme. Specific cleavage of the substrate moiety in the nonfluorescent probe by the target enzyme generates a strong fluorescence signal. To confirm the validity and flexibility of our strategy, we designed and synthesized fluorescence probes for leucine aminopeptidase (Leu-HMRG), fibroblast activation protein (Ac-GlyPro-HMRG), and β-galactosidase (βGal-HMRG). All of these probes were almost nonfluorescent due to the formation of spirocyclic structure, but were converted efficiently to highly fluorescent HMRG by the target enzymes. We confirmed that the probes can be used in living cells. These probes offer great practical advantages, including high sensitivity and rapid response (due to regulation of fluorescence at a single reactive site), as well as resistance to photobleaching, and are expected to be useful for a range of biological and pathological investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
AND-gate contrast agents for enhanced fluorescence-guided surgery
Widen, J. C., Tholen, M., Yim, J. J., Antaris, A., Casey, K. M., Rogalla, S., Klaassen, A., Sorger, J., & Bogyo, M. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00616-6 · Cited by 142
Metadata
- Authors
- Sakabe, M., Asanuma, D., Kamiya, M., Iwatate, R. J., Hanaoka, K., Terai, T., Nagano, T., & Urano, Y.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-12-26
- Volume
- 135
- Issue
- 1
- Pages
- 409-414
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2315018984
- Cited by
- 262
- References
- 0
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rational Design of Highly Sensitive Fluorescence Probes for Protease and Glycosidase Based on Precisely Controlled Spirocyclization. https://app.cochat.ai/papers/10.1021/ja309688m
- The paper
- Sakabe, M., Asanuma, D., Kamiya, M., Iwatate, R. J., Hanaoka, K., Terai, T., Nagano, T., & Urano, Y. (2013). Rational Design of Highly Sensitive Fluorescence Probes for Protease and Glycosidase Based on Precisely Controlled Spirocyclization. Journal of the American Chemical Society. https://doi.org/10.1021/ja309688m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.