The DOI matches its Crossref record.
A Supramolecular Cross-Linked Conjugated Polymer Network for Multiple Fluorescent Sensing
Abstract
A supramolecular cross-linked network was fabricated and demonstrated to act as a multiple fluorescent sensor. It was constructed from a fluorescent conjugated polymer and a bisammonium salt cross-linker driven by dibenzo[24]crown-8/secondary ammonium salt host-guest interactions. Compared with the conjugated polymer, the network has weak fluorescence due to the aggregation of polymer chains. Thanks to the multiple stimuli-responsiveness of host-guest interactions, the fluorescence intensity of the system can be enhanced by four types of signals, including potassium cation, chloride anion, pH increase, and heating. Hence, the network can serve as a cation sensor, an anion sensor, a pH sensor, and a temperature sensor. It can be used in both solution and thin film. Interestingly, exposure of a film made from this supramolecular cross-linked network to ammonia leads to an increase of fluorescence, making it a good candidate for gas detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical Applications of Supramolecular Systems Based on Host–Guest Interactions
Ma, X., & Zhao, Y. (2015) · Chemical Reviews · doi:10.1021/cr500392w · Cited by 1,225
Xue, M., Yang, Y., Chi, X., Yan, X., & Huang, F. (2015) · Chemical Reviews · doi:10.1021/cr5005869 · Cited by 861
Self-citationXia, D., Wang, P., Ji, X., Khashab, N. M., Sessler, J. L., & Huang, F. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00839 · Cited by 734
Self-citationStimuli-Responsive Supramolecular Polymers in Aqueous Solution
Ma, X., & Tian, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar500033n · Cited by 614
Functional Supramolecular Polymers for Biomedical Applications
Dong, R., Zhou, Y., Huang, X., Zhu, X., Lu, Y., & Shen, J. (2015) · Advanced Materials · doi:10.1002/adma.201402975 · Cited by 535
Toward a Single-Layer Two-Dimensional Honeycomb Supramolecular Organic Framework in Water
Zhang, K.-D., Tian, J., Hanifi, D., Zhang, Y., Sue, A. C.-H., Zhou, T.-Y., Zhang, L., Zhao, X., Liu, Y., & Li, Z.-T. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4086935 · Cited by 402
Zhang, Y., Li, Y., & Liu, W. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201401989 · Cited by 355
Liu, K., Kang, Y., Wang, Z., & Zhang, X. (2013) · Advanced Materials · doi:10.1002/adma201302015 · Cited by 337
Yan, X., Cook, T. R., Pollock, J. B., Wei, P., Zhang, Y., Yu, Y., Huang, F., & Stang, P. J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja412249k · Cited by 278
Self-citationAdvanced Polymer Designs for Direct‐Ink‐Write 3D Printing
Li, L., Lin, Q., Tang, M., Duncan, A. J. E., & Ke, C. (2019) · Chemistry – A European Journal · doi:10.1002/chem.201900975 · Cited by 258
Liang, G., Lam, J. W. Y., Qin, W., Li, J., Xie, N., & Tang, B. Z. (2014) · Chem. Commun. · doi:10.1039/c3cc48625g · Cited by 152
Self-citation
Metadata
- Authors
- Ji, X., Yao, Y., Li, J., Yan, X., & Huang, F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-12-26
- Volume
- 135
- Issue
- 1
- Pages
- 74-77
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1988808952
- Cited by
- 412
- References
- 0
- FWCI
- 25.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.