The DOI matches its Crossref record.
Fluorescence Discrimination of Cancer from Inflammation by Molecular Response to COX-2 Enzymes
Abstract
Accurate identification of cancer from inflammation and normal tissue in a rapid, sensitive, and quantitative fashion is important for cancer diagnosis and resection during surgery. Here we report the use of cyclooxygenase-2 as a marker for identification of cancer from inflammation and the design of a novel smart COX-2-specific fluorogenic probe (NANQ-IMC6). The probe's fluorescence is "turned on" in both inflammations and cancers where COX-2 is overexpressed. Intriguingly, the fluorescent emission is quite different at these two sites with different expression level of COX-2. Hence, NANQ-IMC6 can not only distinguish normal cells/tissues from cancer cells/tissues but also distinguish the latter from sites of inflammation lesions by the different fluorescence recognition of NANQ-IMC6 for COX-2 enzymes. Following spraying with the NANQ-IMC6 solution, cancerous tissue, inflamed tissues, and normal tissues can be accurately discriminated in vivo by the unaided eye using a hand-held ultraviolet lamp emitting at 365 nm. So the probe may have potential application varying from cancer inflammation diagnosis to guiding tumor resection during surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent chemosensors: the past, present and future
Wu, D., Sedgwick, A. C., Gunnlaugsson, T., Akkaya, E. U., Yoon, J., & James, T. D. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00240h · Cited by 2,002
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Small-Molecule Two-Photon Probes for Bioimaging Applications
Kim, H. M., & Cho, B. R. (2015) · Chemical Reviews · doi:10.1021/cr5004425 · Cited by 1,047
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Self-citationFluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Fluorescent Probes for Disease Diagnosis
Wang, X., Ding, Q., Groleau, R. R., Wu, L., Mao, Y., Che, F., Kotova, O., Scanlan, E. M., Lewis, S. E., Li, P., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00776 · Cited by 543
Carbon Dots for In Vivo Bioimaging and Theranostics
Du, J., Xu, N., Fan, J., Sun, W., & Peng, X. (2019) · Small · doi:10.1002/smll.201805087 · Cited by 488
Self-citationNiu, H., Liu, J., O’Connor, H. M., Gunnlaugsson, T., James, T. D., & Zhang, H. (2023) · Chemical Society Reviews · doi:10.1039/d1cs01097b · Cited by 449
Self-citationPrecise nanomedicine for intelligent therapy of cancer
Chen, H., Gu, Z., An, H., Chen, C., Chen, J., Cui, R., Chen, S., Chen, W., Chen, X., Chen, X., et al. (2018) · Science China Chemistry · doi:10.1007/s11426-018-9397-5 · Cited by 409
Activity-Based Sensing and Theranostic Probes Based on Photoinduced Electron Transfer
Sun, W., Li, M., Fan, J., & Peng, X. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00340 · Cited by 364
Self-citationActivity‐Based NIR Enzyme Fluorescent Probes for the Diagnosis of Tumors and Image‐Guided Surgery
Li, H., Kim, D., Yao, Q., Ge, H., Chung, J., Fan, J., Wang, J., Peng, X., & Yoon, J. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202009796 · Cited by 363
Self-citation
Metadata
- Authors
- Zhang, H., Fan, J., Wang, J., Dou, B., Zhou, F., Cao, J., Qu, J., Cao, Z., Zhao, W., & Peng, X.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-11-07
- Volume
- 135
- Issue
- 46
- Pages
- 17469-17475
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2093335008
- Cited by
- 169
- References
- 0
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.