The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Chemiluminescent Detection of Enzymatically Produced Hydrogen Sulfide: Substrate Hydrogen Bonding Influences Selectivity for H2S over Biological Thiols
Open accessAbstract
Hydrogen sulfide (H2S) is now recognized as an important biological regulator and signaling agent that is active in many physiological processes and diseases. Understanding the important roles of this emerging signaling molecule has remained challenging, in part due to the limited methods available for detecting endogenous H2S. Here we report two reaction-based ChemiLuminescent Sulfide Sensors, CLSS-1 and CLSS-2, with strong luminescence responses toward H2S (128- and 48-fold, respectively) and H2S detection limits (0.7 ± 0.3, 4.6 ± 2.0 μM, respectively) compatible with biological H2S levels. CLSS-2 is highly selective for H2S over other reactive sulfur, nitrogen, and oxygen species (RSONS) including GSH, Cys, Hcy, S2O3(2–), NO2(–), HNO, ONOO(–), and NO. Despite its similar chemical structure, CLSS-1 displays lower selectivity toward amino acid-derived thiols than CLSS-2. The origin of this differential selectivity was investigated using both computational DFT studies and NMR experiments. Our results suggest a model in which amino acid binding to the hydrazide moiety of the luminol-derived probes provides differential access to the reactive azide in CLSS-1 and CLSS-2, thus eroding the selectivity of CLSS-1 for H2S over Cys and GSH. On the basis of its high selectivity for H2S, we used CLSS-2 to detect enzymatically produced H2S from isolated cystathionine γ-lyase (CSE) enzymes (p < 0.001) and also from C6 cells expressing CSE (p < 0.001). CLSS-2 can readily differentiate between H2S production in active CSE and CSE inhibited with β-cyanoalanine (BCA) in both isolated CSE enzymes (p < 0.005) and in C6 cells (p < 0.005). In addition to providing a highly sensitive and selective reaction-based tool for chemiluminescent H2S detection and quantification, the insights into substrate–probe interactions controlling the selectivity for H2S over biologically relevant thiols may guide the design of other selective H2S detection scaffolds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
H 2 S as a Physiologic Vasorelaxant: Hypertension in Mice with Deletion of Cystathionine γ-Lyase
Yang, G., Wu, L., Jiang, B., Yang, W., Qi, J., Cao, K., Meng, Q., Mustafa, A. K., Mu, W., Zhang, S., et al. (2008) · Science · doi:10.1126/science.1162667 · Cited by 2,310
Filipovic, M. R., Miljkovic, J. L., Nauser, T., Royzen, M., Klos, K., Shubina, T., Koppenol, W. H., Lippard, S. J., & Ivanović-Burmazović, I. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3009693 · Cited by 336
Hydrogen sulfide enhances ulcer healing in rats
Wallace, J. L., Dicay, M., McKnight, W., & Martin, G. R. (2007) · The FASEB Journal · doi:10.1096/fj.07-8669com · Cited by 236
Cited by
Lin, V. S., Chen, W., Xian, M., & Chang, C. J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00298a · Cited by 1,037
Fluorescent probes for hydrogen sulfide detection and bioimaging
Yu, F., Han, X., & Chen, L. (2014) · Chem. Commun. · doi:10.1039/c4cc03312d · Cited by 402
Metadata
- Authors
- Bailey, T. S., & Pluth, M. D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-10-23
- Volume
- 135
- Issue
- 44
- Pages
- 16697-16704
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2082607647
- Cited by
- 178
- References
- 3
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.