The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Insight into Proton Transfer in Phosphotungstic Acid Functionalized Mesoporous Silica-Based Proton Exchange Membrane Fuel Cells
Abstract
We have developed for fuel cells a novel proton exchange membrane (PEM) using inorganic phosphotungstic acid (HPW) as proton carrier and mesoporous silica as matrix (HPW-meso-silica) . The proton conductivity measured by electrochemical impedance spectroscopy is 0.11 S cm(-1) at 90 °C and 100% relative humidity (RH) with a low activation energy of ∼14 kJ mol(-1). In order to determine the energetics associated with proton migration within the HPW-meso-silica PEM and to determine the mechanism of proton hopping, we report density functional theory (DFT) calculations using the generalized gradient approximation (GGA). These DFT calculations revealed that the proton transfer process involves both intramolecular and intermolecular proton transfer pathways. When the adjacent HPWs are close (less than 17.0 Å apart), the calculated activation energy for intramolecular proton transfer within a HPW molecule is higher (29.1-18.8 kJ/mol) than the barrier for intermolecular proton transfer along the hydrogen bond. We find that the overall barrier for proton movement within the HPW-meso-silica membranes is determined by the intramolecular proton transfer pathway, which explains why the proton conductivity remains unchanged when the weight percentage of HPW on meso-silica is above 67 wt %. In contrast, the activation energy of proton transfer on a clean SiO2 (111) surface is computed to be as high as ∼40 kJ mol(-1), confirming the very low proton conductivity on clean silica surfaces observed experimentally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleaning the air and improving health with hydrogen fuel-cell vehicles
Jacobson, M. Z., Colella, W. G., & Golden, D. M. (2005) · Science · doi:10.1126/science.1109157 · Cited by 1,023
Cited by
Mesoporous materials for energy conversion and storage devices
Li, W., Liu, J., & Zhao, D. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.23 · Cited by 1,388
Magnetic field alignment of stable proton-conducting channels in an electrolyte membrane
Liu, X., Li, Y., Xue, J., Zhu, W., Zhang, J., Yin, Y., Qin, Y., Jiao, K., Du, Q., Cheng, B., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08622-2 · Cited by 465
Zatoń, M., Rozière, J., & Jones, D. J. (2017) · Sustainable Energy & Fuels · doi:10.1039/c7se00038c · Cited by 435
Metadata
- Authors
- Zhou, Y., Yang, J., Su, H., Zeng, J., Jiang, S. P., & Goddard, W. A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-03-25
- Volume
- 136
- Issue
- 13
- Pages
- 4954-4964
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2095924573
- Cited by
- 171
- References
- 1
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.