The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Self-Assembled Near-Infrared Dye Nanoparticles as a Selective Protein Sensor by Activation of a Dormant Fluorophore
Abstract
Design of selective sensors for a specific analyte in blood serum, which contains a large number of proteins, small molecules, and ions, is important in clinical diagnostics. While metal and polymeric nanoparticle conjugates have been used as sensors, small molecular assemblies have rarely been exploited for the selective sensing of a protein in blood serum. Herein we demonstrate how a nonspecific small molecular fluorescent dye can be empowered to form a selective protein sensor as illustrated with a thiol-sensitive near-IR squaraine (Sq) dye (λabs= 670 nm, λem= 700 nm). The dye self-assembles to form nonfluorescent nanoparticles (Dh = 200 nm) which selectively respond to human serum albumin (HSA) in the presence of other thiol-containing molecules and proteins by triggering a green fluorescence. This selective response of the dye nanoparticles allowed detection and quantification of HSA in blood serum with a sensitivity limit of 3 nM. Notably, the Sq dye in solution state is nonselective and responds to any thiol-containing proteins and small molecules. The sensing mechanism involves HSA specific controlled disassembly of the Sq nanoparticles to the molecular dye by a noncovalent binding process and its subsequent reaction with the thiol moiety of the protein, triggering the green emission of a dormant fluorophore present in the dye. This study demonstrates the power of a self-assembled small molecular fluorophore for protein sensing and is a simple chemical tool for the clinical diagnosis of blood serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Cited by
Shao, A., Xie, Y., Zhu, S., Guo, Z., Zhu, S., Guo, J., Shi, P., James, T. D., Tian, H., & Zhu, W. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201501478 · Cited by 403
Shi, B., Jie, K., Zhou, Y., Zhou, J., Xia, D., & Huang, F. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.5b11676 · Cited by 298
Facile synthesis of AIEgens with wide color tunability for cellular imaging and therapy
Xu, W., Lee, M. M. S., Zhang, Z., Sung, H. H. Y., Williams, I. D., Kwok, R. T. K., Lam, J. W. Y., Wang, D., & Tang, B. Z. (2019) · Chemical Science · doi:10.1039/c8sc05805a · Cited by 148
Dong, X., Zhang, G., Shi, J., Wang, Y., Wang, M., Peng, Q., & Zhang, D. (2017) · Chem. Commun. · doi:10.1039/c7cc07092f · Cited by 54
Metadata
- Authors
- Anees, P., Sreejith, S., & Ajayaghosh, A.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-09-16
- Volume
- 136
- Issue
- 38
- Pages
- 13233-13239
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1978832930
- Cited by
- 178
- References
- 1
- FWCI
- 11.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-Assembled Near-Infrared Dye Nanoparticles as a Selective Protein Sensor by Activation of a Dormant Fluorophore. https://app.cochat.ai/papers/10.1021/ja503850b
- The paper
- Anees, P., Sreejith, S., & Ajayaghosh, A. (2014). Self-Assembled Near-Infrared Dye Nanoparticles as a Selective Protein Sensor by Activation of a Dormant Fluorophore. Journal of the American Chemical Society. https://doi.org/10.1021/ja503850b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.