The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Turn-On Fluorescence Sensing of Nucleoside Polyphosphates Using a Xanthene-Based Zn(II) Complex Chemosensor
Abstract
Fluorescence sensing with small molecular chemosensors is a versatile technique for elucidation of function of various biological substances. We now report a new fluorescent chemosensor for nucleoside polyphosphates such as ATP using metal-anion coordination chemistry. The chemosensor 1-2Zn(II) is comprised of the two sites of 2,2'-dipicolylamine (Dpa)-Zn(II) as the binding motifs and xanthene as a fluorescent sensing unit for nucleoside polyphosphates. The chemosensor 1-2Zn(II) selectively senses nucleoside polyphosphates with a large fluorescence enhancement (F/F(o) > 15) and strong binding affinity (K(app) approximately = 1 x 10(6) M(-1)), whereas no detectable fluorescence change was induced by monophosphate species and various other anions. The 'turn-on,' fluorescence of 1-2Zn(II) is based on a new mechanism, which involves the binding-induced recovery of the conjugated form of the xanthene ring from its nonfluorescent deconjugated state which was formed by an unprecedented nucleophilic attack of zinc-bound water. The selective and highly sensitive ability of 1-2Zn(II) to detect nucleoside polyphosphates enables its bioanalytical applications in fluorescence visualization of ATP particulate stores in living cells, demonstrating the potential utility of 1-2Zn(II).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A design of fluorescent probes for superoxide based on a nonredox mechanism
Maeda, H., Yamamoto, K., Nomura, Y., Kohno, I., Hafsi, L., Ueda, N., Yoshida, S., Fukuda, M., Fukuyasu, Y., Yamauchi, Y., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja047018k · Cited by 196
Cited by
Applications of Supramolecular Anion Recognition
Busschaert, N., Caltagirone, C., Van Rossom, W., & Gale, P. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00099 · Cited by 1,249
Application of Metal Coordination Chemistry To Explore and Manipulate Cell Biology
Haas, K. L., & Franz, K. J. (2009) · Chemical Reviews · doi:10.1021/cr900134a · Cited by 984
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Artificial Receptors for the Recognition of Phosphorylated Molecules
Hargrove, A. E., Nieto, S., Zhang, T., Sessler, J. L., & Anslyn, E. V. (2011) · Chemical Reviews · doi:10.1021/cr100242s · Cited by 649
Metadata
- Authors
- Ojida, A., Takashima, I., Kohira, T., Nonaka, H., & Hamachi, I.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-14
- Volume
- 130
- Issue
- 36
- Pages
- 12095-12101
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2022842176
- Cited by
- 330
- References
- 1
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.