Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Giant Dendritic Molecular Electrochrome Batteries with Ferrocenyl and Pentamethylferrocenyl Termini

Ornelas, Catia, Ruiz, Jaime, Belin, Colette, Astruc, Didier·2009·Journal of the American Chemical Society

Abstract

Giant redox dendrimers were synthesized with ferrocenyl and pentamethylferrocenyl termini up to a theoretical number of 3(9) tethers (seventh generation). Lengthening of the tethers proved to be a reliable strategy to overcome the bulk constraint at the dendrimers periphery. These redox metallodendrimers were characterized by (1)H, (13)C, and (29)Si NMR; MALDI-TOF mass spectrometry (for the low generations); elemental analysis; UV-vis spectroscopy; dynamic light scattering (DLS); atomic force microscopy (AFM); electron-force microscopy (EFM) for half- or fully oxidized dendrimers; cyclic voltammetry; and coulometry. UV-vis spectroscopy, coulometry, and analytical data are consistent with an increasing amount of defects as the generation number increases, with this amount remaining relatively weak up to G(5). AFM shows that the dendrimers form aggregates of discrete size on the mica surface, recalling the agglomeration of metal atoms in monodisperse nanoparticles. Cyclic voltammetry reveals full chemical and electrochemical reversibility up to G(7), showing that electron transfer is fast among the flexible peripheral redox sites. Indeed, the redox stability of these new electrochromic dendrimers, i.e., a battery behavior, was established by complete chemical oxido-reduction cycles, and the blue 17-electron ferrocenium and deep-green mixed-valence Fe(III)/Fe(II) dendritic complexes were isolated and characterized. AFM studies also show the reversible dendrimer size changes from upon redox switching between Fe(II) and Fe(III), suggesting a breathing mechanism controlled by the redox potential. Considerable adsorption of high-generation dendrimers on Pt electrodes such as G(7)-Fc allows the easy formation of modified electrodes that sense the ATP anion only involving the electrostatic factor even in the absence of any other type of interaction with the redox tethers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja8062343

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
Ornelas, C., Ruiz, J., Belin, C., & Astruc, D.
Venue
Journal of the American Chemical Society
Published
2008-12-29
Volume
131
Issue
2
Pages
590-601
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W1987240268
Cited by
188
References
1
FWCI
14.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Giant Dendritic Molecular Electrochrome Batteries with Ferrocenyl and Pentamethylferrocenyl Termini. https://app.cochat.ai/papers/10.1021/ja8062343
The paper
Ornelas, C., Ruiz, J., Belin, C., & Astruc, D. (2009). Giant Dendritic Molecular Electrochrome Batteries with Ferrocenyl and Pentamethylferrocenyl Termini. Journal of the American Chemical Society. https://doi.org/10.1021/ja8062343

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.