The DOI matches its Crossref record.
Multiple Core−Shell Functionalized Colloidal Mesoporous Silica Nanoparticles
Abstract
The selective functionalization of the inner and outer surfaces of colloidal mesoporous silica (CMS) nanoparticles with different trialkoxysilanes, following a newly developed delayed co-condensation approach, results in bifunctional CMS. Complementary CMS nanoparticles were prepared with two different functional groups located either on the outer shell or in the inner core of the particle. The identification and localization of the functional groups was achieved by means of different techniques including zeta potential, nitrogen sorption measurements, and fluorescence spectroscopy. This last technique was applied to fluorescein isothiocyanate (FITC)-labeled CMS featuring aminopropyl functional groups on the periphery or the internal pore surface of the particles. Fluorescence quenching experiments were carried out with dodecanethiolate-stabilized gold nanoparticles having a diameter greater than the pore size of the CMS. It could be shown that fluorescence quenching occurs only when the FITC is positioned on the outer surface of the CMS nanoparticles, whereas no quenching was observed for FITC located in the inner core of the nanoparticle. These results clearly confirm the controlled localization of the aminopropyl groups in the nanometer space of the CMS particles. Our approach thus offers the opportunity to synthesize, in a novel multistep co-condensation strategy, various bifunctional mesoporous nanoparticles with controlled localization of different functional groups in the inner core or on the outer shell of the nanoparticle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lu, J., Liong, M., Li, Z., Zink, J. I., & Tamanoi, F. (2010) · Small · doi:10.1002/smll.201000538 · Cited by 1,074
Chen, L., Mccrate, J. M., Lee, J. C.-M., & Li, H. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/10/105708 · Cited by 465
Wang, H., Jeong, H. Y., Imura, M., Wang, L., Radhakrishnan, L., Fujita, N., Castle, T., Terasaki, O., & Yamauchi, Y. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2058617 · Cited by 403
Nanoparticles for Biomedical Imaging: Fundamentals of Clinical Translation
Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00031 · Cited by 351
Cauda, V., Argyo, C., & Bein, T. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm01390k · Cited by 254
Self-citationThe blood clearance kinetics and pathway of polymeric micelles in cancer drug delivery
Sun, X., Wang, G., Zhang, H., Hu, S., Liu, X., Tang, J., & Shen, Y. (2018) · ACS Nano · doi:10.1021/acsnano.8b02830 · Cited by 253
Cauda, V., Engelke, H., Sauer, A., Arcizet, D., Rädler, J., & Bein, T. (2010) · Nano Letters · doi:10.1021/nl100991w · Cited by 155
Self-citation
Metadata
- Authors
- Cauda, V., Schlossbauer, A., Kecht, J., Zürner, A., & Bein, T.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-22
- Volume
- 131
- Issue
- 32
- Pages
- 11361-11370
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1991280014
- Cited by
- 235
- References
- 0
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.