Nafion Structural Phenomena at Platinum and Carbon Interfaces
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Neutron reflectometry was used to examine the interactions of polymer electrolyte fuel cell (PEFC) materials that comprise the triple-phase interface. Smooth, idealized layers of Nafion on glassy carbon (GC) and Pt surfaces were used to experimentally model the PEFC electrode interfaces. Different multilayer structures of Nafion were found in contact with the Pt or GC surfaces. These structures showed separate hydrophobic and hydrophilic domains formed within the Nafion layer when equilibrated with saturated D(2)O vapor. A hydrophobic Nafion region was formed adjacent to a Pt film. However, when Nafion was in contact with a PtO surface, the Nafion at the Pt interface became hydrophilic. The adsorbed oxide layer caused a long-range restructuring of the perfluorosulfonic acid polymer chains that comprise Nafion. The thicknesses of the hydrophobic and hydrophilic domains changed to the same magnitude when the oxide layer was present compared to a thin hydrophobic domain in contact with Pt. A three-layer Nafion structure was formed when Nafion was in direct contact with GC. The findings in this research are direct experimental evidence that both the interfacial and long-range structural properties of Nafion are affected by the material with which it is in contact. Evidence of physical changes of aged Nafion films was obtained, and the results showed a permanent increase in the thickness of the Nafion film and a decrease in the scattering length density (SLD), which are attributed to irreversible swelling of the Nafion film. The aging also resulted in a decrease in the SLD of the GC substrate, which is likely due to either an increase in surface oxidation of the carbon or loss of carbon mass at the GC surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
State of Understanding of Nafion
Mauritz, K. A., & Moore, R. B. (2004) · Chemical Reviews · doi:10.1021/cr0207123 · Cited by 4,791
Particle Size Effects for Oxygen Reduction on Highly Dispersed Platinum in Acid Electrolytes
Kinoshita, K. (1990) · Journal of The Electrochemical Society · doi:10.1149/1.2086566 · Cited by 854
Markovic, N., Gasteiger, H., & Ross, P. N. (1997) · Journal of The Electrochemical Society · doi:10.1149/1.1837646 · Cited by 564
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Wiers, B. M., Foo, M.-L., Balsara, N. P., & Long, J. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205827z · Cited by 454
Unexplained transport resistances for low-loaded fuel-cell catalyst layers
Weber, A. Z., & Kusoglu, A. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta02952f · Cited by 333
Carbon Nanotube and Graphene‐based Bioinspired Electrochemical Actuators
Kong, L., & Chen, W. (2014) · Advanced Materials · doi:10.1002/adma.201303432 · Cited by 307
Molecular Dynamics Simulations on O 2 Permeation through Nafion Ionomer on Platinum Surface
Jinnouchi, R., Kudo, K., Kitano, N., & Morimoto, Y. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2015.12.031 · Cited by 283
Metadata
- Authors
- Wood, D. L., Chlistunoff, J., Majewski, J., & Borup, R. L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-11-19
- Volume
- 131
- Issue
- 50
- Pages
- 18096-18104
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2035934892
- Cited by
- 141
- References
- 3
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.