The DOI matches its Crossref record.
Polarity-Sensitive Coumarins Tailored to Live Cell Imaging
Abstract
Polarity-dependent fluorescent probes are recently attracting interest for high-resolution cell imaging. Following a stepwise rational approach, we prepared and tested a toolbox of new coumarin derivatives tailored to in vivo imaging applications. Our compounds are characterized by a donor-(coumarin core)-acceptor molecular structure, where the electron donor is represented by alkylether or naphthyl groups, and the electron acceptor is represented by benzothiazene and cyano groups. Prior to synthesis, the substitution patterns were screened by computational methods to provide functional fluorescent derivatives easy to synthesize, and with excitation in the visible region of spectrum. We set up a robust synthetic procedure tunable on the substitution patterns to achieve. These coumarins possess excellent fluorescence quantum yields (up to 0.95), high molar extinction coefficients (up to 46,000 M(-1) cm(-1)), and large Stokes shifts. Furthermore, they display strong solvatochromism, being almost non-emissive in water and very fluorescent in less polar media (up to 780-fold enhancement in brightness). The solvatochromism of these compounds can be accounted for by a photophysical method encompassing two communicating excited states. When tested on cultured cells, the results showed that the developed coumarins were not harmful and their photophysical properties were unchanged compared to free solution. According to the determined solvatochromic properties, the coumarin fluorescence was detected only in the most lipophilic environments of the cell. The prepared compounds represent remarkable tools to investigate subtle biochemical processes in the cell environment after appropriate conjugation to biomolecules, and at the same time constitute the basis for further engineering of a new generation of biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Fluorescent Probes for Sensing and Imaging within Specific Cellular Organelles
Zhu, H., Fan, J., Du, J., & Peng, X. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00292 · Cited by 984
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Current Developments of Coumarin Compounds in Medicinal Chemistry
Peng, X.-M., L.V. Damu, G., & He Zhou, C. (2013) · Current Pharmaceutical Design · doi:10.2174/1381612811319210013 · Cited by 504
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Metadata
- Authors
- Signore, G., Nifosì, R., Albertazzi, L., Storti, B., & Bizzarri, R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-02-03
- Volume
- 132
- Issue
- 4
- Pages
- 1276-1288
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2014760978
- Cited by
- 264
- References
- 0
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polarity-Sensitive Coumarins Tailored to Live Cell Imaging. https://app.cochat.ai/papers/10.1021/ja9050444
- The paper
- Signore, G., Nifosì, R., Albertazzi, L., Storti, B., & Bizzarri, R. (2010). Polarity-Sensitive Coumarins Tailored to Live Cell Imaging. Journal of the American Chemical Society. https://doi.org/10.1021/ja9050444
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.