The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Recyclable Nanobiocatalyst for Enantioselective Sulfoxidation: Facile Fabrication and High Performance of Chloroperoxidase-Coated Magnetic Nanoparticles with Iron Oxide Core and Polymer Shell
Abstract
Magnetic nanoparticles (MNPs) with a core diameter of 30 nm comprising several iron oxide crystals, a poly(glycidyl methacrylate) (PGMA) shell with a thickness of 30 nm, and a surface coated with chloroperoxidase (CPO) were facilely fabricated as a nanobiocatalyst for asymmetric sulfoxidation. The covalently bound CPO did not change the original conformation of the active site and showed the same catalytic activity and enantioselectivity as free CPO for the sulfoxidation of thioanisole to produce (R)-methyl phenyl sulfoxide in >99% ee. The thick PGMA shell significantly increased the stability of the nanobiocatalyst: no loss of the sulfoxidation activity was observed after 11 times of recycling and reuse of the catalyst. Thus, the nanobiocatalyst fabricated here showed the best performance among nanosized biocatalyst particles regarding both the retaining of free enzyme activity and the recycling of catalyst. This is also the first example of a nanobiocatalyst for asymmetric oxidation, and the concept could be generally applicable for fabricating active and recyclable nanobiocatalysts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Cited by
Potential applications of enzymes immobilized on/in nano materials: A review
Ansari, S. A., & Husain, Q. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.005 · Cited by 1,118
New and classic families of secreted fungal heme peroxidases
Hofrichter, M., Ullrich, R., Pecyna, M. J., Liers, C., & Lundell, T. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2633-0 · Cited by 527
Recyclable Stereoselective Catalysts
Trindade, A. F., Gois, P. M. P., & Afonso, C. A. M. (2009) · Chemical Reviews · doi:10.1021/cr800200t · Cited by 450
Enzyme-mediated oxidations for the chemist
Hollmann, F., Arends, I. W. C. E., Buehler, K., Schallmey, A., & Bühler, B. (2011) · Green Chem. · doi:10.1039/c0gc00595a · Cited by 425
Chen, Q., Chen, J., Liang, C., Feng, L., Dong, Z., Song, X., Song, G., & Liu, Z. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.11.006 · Cited by 188
Metadata
- Authors
- Wang, W., Xu, Y., Wang, D. I. C., & Li, Z.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-24
- Volume
- 131
- Issue
- 36
- Pages
- 12892-12893
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1985440948
- Cited by
- 171
- References
- 1
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.