The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Engineered Ionic Gates for Ion Conduction Based on Sodium and Potassium Activated Nanochannels
Abstract
In living systems, ion conduction plays a major role in numerous cellular processes and can be controlled by biological ion channels in response to specific environmental stimuli. This article describes biomimetic ionic gates for ion conduction based on sodium and potassium activated nanochannels. The Na(+) activated ionic gate and K(+) activated ionic gate were developed by immobilizing the alkali metal cation-responsive functional molecules, 4'-aminobenzo-15-crown-5 and 4'-aminobenzo-18-crown-6, respectively, onto the conical polyimide nanochannels. When the ionic gate was in the presence of the specific alkali metal cation, positively charged complexes formed between the crown ether and the alkali metal cation. On the basis of the resulting changes in surface charge, wettability and effective pore size, the nanochannel can achieve reversible switching. The switching behaviors of the two complexes differed due to the differences in binding strength between the two complexes. The Na(+) activated ionic gate is able to open and close to control the ion conduction through the nanochannel, and the K(+) activated ionic gate enables selective cation and anion conduction through the nanochannel. The Na(+) and K(+) activated ionic gates show great promise for use in clinical medicine, biosensors and drug delivery based on their high sensitivity and selectivity of being activated, and good stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Mechanisms of Human Hypertension
Lifton, R. P., Gharavi, A. G., & Geller, D. S. (2001) · Cell · doi:10.1016/s0092-8674(01)00241-0 · Cited by 1,686
Cited by
Biological Activity of Ionic Liquids and Their Application in Pharmaceutics and Medicine
Egorova, K. S., Gordeev, E. G., & Ananikov, V. P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00562 · Cited by 1,649
An Overview of the Development of Flexible Sensors
Han, S., Peng, H., Sun, Q., Venkatesh, S., Chung, K., Lau, S. C., Zhou, Y., & Roy, V. A. L. (2017) · Advanced Materials · doi:10.1002/adma.201700375 · Cited by 771
Design principles of ion selective nanostructured membranes for the extraction of lithium ions
Razmjou, A., Asadnia, M., Hosseini, E., Habibnejad Korayem, A., & Chen, V. (2019) · Nature Communications · doi:10.1038/s41467-019-13648-7 · Cited by 616
Bioinspired smart asymmetric nanochannel membranes
Zhang, Z., Wen, L., & Jiang, L. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00688h · Cited by 477
Self-citationBroza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Metadata
- Authors
- Liu, Q., Xiao, K., Wen, L., Lu, H., Liu, Y., Kong, X.-Y., Xie, G., Zhang, Z., Bo, Z., & Jiang, L.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-09-11
- Volume
- 137
- Issue
- 37
- Pages
- 11976-11983
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2414098485
- Cited by
- 225
- References
- 1
- FWCI
- 8.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.