The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Remarkable Enhancement of Chemiluminescent Signal by Dioxetane–Fluorophore Conjugates: Turn-ON Chemiluminescence Probes with Color Modulation for Sensing and Imaging
Abstract
Chemiluminescence is among the most sensitive methods for achieving a high signal-to-noise ratio in various chemical and biological applications. We have developed a modular practical synthetic route for preparation of turn-ON fluorophore-tethered dioxetane chemiluminescent probes. The chemiluminescent emission of the probes was significantly amplified through an energy-transfer mechanism under physiological conditions. Two probes were composed with green and near-infrared (NIR) fluorescent dyes tethered to Schaap's dioxetane. While both probes were able to provide chemiluminescence in vivo images following subcutaneous injection, only the NIR probe could provide a chemiluminescence image following intraperitoneal injection. These are the first in vivo images produced by Schaap's dioxetane chemiluminescence probes with no need of an enhancer. Previously, chemiluminescence cell images could only be obtained with a luciferin-based probe. Our NIR probe was able to image cells transfected with β-galactosidase gene by chemiluminescence microscopy. We also report, for the first time, the instability of dioxetane-fluorophore conjugates to ambient light. Our synthetic route effectively overcomes this limitation through a late-stage functionalization of the dioxetane intermediate. We anticipate that our practical synthetic methodology will be useful for preparation of various chemiluminescent probes for numerous applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Cited by
Molecular optical imaging probes for early diagnosis of drug-induced acute kidney injury
Huang, J., Li, J., Lyu, Y., Miao, Q., & Pu, K. (2019) · Nature Materials · doi:10.1038/s41563-019-0378-4 · Cited by 721
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
A General Method To Increase Stokes Shift by Introducing Alternating Vibronic Structures
Ren, T.-B., Xu, W., Zhang, W., Zhang, X.-X., Wang, Z.-Y., Xiang, Z., Yuan, L., & Zhang, X.-B. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b04404 · Cited by 443
Green, O., Eilon, T., Hananya, N., Gutkin, S., Bauer, C. R., & Shabat, D. (2017) · ACS Central Science · doi:10.1021/acscentsci.7b00058 · Cited by 336
Self-citation
Metadata
- Authors
- Hananya, N., Eldar Boock, A., Bauer, C. R., Satchi-Fainaro, R., & Shabat, D.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-09-29
- Volume
- 138
- Issue
- 40
- Pages
- 13438-13446
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2521075809
- Cited by
- 249
- References
- 1
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.