The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Intraligand Charge Transfer Sensitization on Self-Assembled Europium Tetrahedral Cage Leads to Dual-Selective Luminescent Sensing toward Anion and Cation
Abstract
Luminescent supramolecular lanthanide edifices have many potential applications in biology, environments, and materials science. However, it is still a big challenge to improve the luminescent performance of multinuclear lanthanide assemblies in contrast to their mononuclear counterparts. Herein, we demonstrate that combination of intraligand charge transfer (ILCT) sensitization and coordination-driven self-assembly gives birth to bright Eu III tetrahedral cages with a record emission quantum yield of 23.1%. The ILCT sensitization mechanism has been unambiguously confirmed by both time-dependent density functional theory calculation and femtosecond transient absorption studies. Meanwhile, dual-responsive sensing toward both anions and cations has been demonstrated making use of the ILCT transition on the ligand. Without introduction of additional recognition units, high sensitivity and selectivity are revealed for the cage in both turn-off luminescent sensing toward I – and turn-on sensing toward Cu 2+ . This study offers important design principles for the future development of luminescent lanthanide molecular materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Cited by
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Metadata
- Authors
- Liu, C.-L., Zhang, R.-L., Lin, C.-S., Zhou, L.-P., Cai, L.-X., Kong, J.-T., Yang, S.-Q., Han, K.-L., & Sun, Q.-F.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-09-01
- Volume
- 139
- Issue
- 36
- Pages
- 12474-12479
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2750396513
- Cited by
- 166
- References
- 1
- FWCI
- 7.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraligand Charge Transfer Sensitization on Self-Assembled Europium Tetrahedral Cage Leads to Dual-Selective Luminescent Sensing toward Anion and Cation. https://app.cochat.ai/papers/10.1021/jacs.7b05157
- The paper
- Liu, C.-L., Zhang, R.-L., Lin, C.-S., Zhou, L.-P., Cai, L.-X., Kong, J.-T., Yang, S.-Q., Han, K.-L., & Sun, Q.-F. (2017). Intraligand Charge Transfer Sensitization on Self-Assembled Europium Tetrahedral Cage Leads to Dual-Selective Luminescent Sensing toward Anion and Cation. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.7b05157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.