Cited by 61Nanomaterials and Printing TechnologiesGold and Silver Nanoparticles Synthesis and ApplicationsAdvanced Sensor and Energy Harvesting Materials

The DOI matches its Crossref record.

Rapid Electrochemical Cleaning Silver Nanowire Thin Films for High-Performance Transparent Conductors

Ge, Yongjie, Liu, Jianfang, Liu, Xiaojun, Hu, Jiawen, Duan, Xidong, Duan, Xiangfeng·2019·Journal of the American Chemical Society

Abstract

Silver nanowire (Ag-NW) thin films are of considerable interest for next-generation transparent conductors (TCs). However, their carrier transport properties are largely plagued by the residual polyvinylpyrrolidone (PVP) ligands on surface that were introduced during the synthesis of the Ag-NWs. Here we report a rapid electrochemical cleaning strategy to thoroughly remove the surface PVP ligands and greatly improve the carrier transport properties of the Ag-NW thin films while not affecting their transmittance. In particular, we show a negative electrochemical potential near the hydrogen adsorption/evolution regime can effectively displace all PVP ligands from the Ag-NW surface in 5-15 s, producing ultraclean interfaces between Ag-NW/Ag-NW junctions or Ag-NW film/active layer junction in a stacked optoelectronic device. We show that the removal of the PVP ligands can substantially reduce the sheet resistance of the Ag-NW thin film from 49 to 13 ohm/sq (with 90.91% transmittance at 550 nm) and reduce the interfacial resistance at the Ag-NW film/active layer interface by 94.3%. Such improved Ag-NW thin films can greatly enhance the sensitivity of the wearable strain sensor and the current collection efficiency of the vertically stacked devices constructed from the sandwiched thin films. These results demonstrate that the electrochemical cleaning approach is highly effective in removing surface ligands and improving both the in-plane and the out-of-plane carrier transport properties of the Ag-NW thin films, greatly facilitating their applications in electronic and optoelectronic devices.

Overview

Integrity signals

Registry

Crossref · 10.1021/jacs.9b02497

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 46

  1. 10.1039/C7RA10889C · DOI
  2. 10.1039/C5TC03419A · DOI
  3. 10.1021/acsami.7b14040 · DOI
  4. 10.1021/jacs.7b03227 · DOI
  5. 10.1088/0957-4484/24/45/452001 · DOI
  6. 10.1002/adma.201402710 · DOI
  7. 10.1016/j.jcis.2016.07.079 · DOI
  8. 10.1002/smll.201602581 · DOI
  9. 10.1016/j.nantod.2015.11.005 · DOI
  10. 10.1002/smll.201502988 · DOI
  11. 10.1126/sciadv.1700159 · DOI
  12. 10.1021/acs.chemrev.6b00179 · DOI
  13. 10.1002/smll.201501772 · DOI
  14. 10.1016/j.mseb.2017.05.002 · DOI
  15. 10.1021/nl034312m · DOI
  16. 10.1021/nn403324t · DOI
  17. 10.1021/acsnano.5b05469 · DOI
  18. 10.1007/s40820-014-0018-0 · DOI
  19. 10.1039/C5RA28003F · DOI
  20. 10.1002/adfm.201705409 · DOI
  21. 10.1021/nl073296g · DOI
  22. 10.1021/nn504969z · DOI
  23. 10.1021/nn4065567 · DOI
  24. 10.1021/nn405887k · DOI
  25. 10.1002/smll.201402474 · DOI
  26. 10.1002/adfm.201706010 · DOI
  27. 10.1002/adma.201600358 · DOI
  28. 10.1021/acs.nanolett.6b04613 · DOI
  29. 10.1002/adma.201701479 · DOI
  30. 10.1021/acs.nanolett.7b05060 · DOI
  31. 10.1021/jacs.7b07851 · DOI
  32. 10.1021/ja00079a021 · DOI
  33. 10.1039/b305867k · DOI
  34. 10.1016/j.elecom.2013.11.019 · DOI
  35. 10.1038/ncomms8867 · DOI
  36. 10.1021/nn403444j · DOI
  37. 10.1039/B714072J · DOI
  38. 10.1021/nn400414h · DOI
  39. 10.1016/S0013-4686(00)00523-5 · DOI
  40. 10.1021/jp8055653 · DOI
  41. 10.1021/jp5025526 · DOI
  42. 10.1007/BF01016894 · DOI
  43. 10.1016/S0022-0728(96)04719-5 · DOI
  44. 10.1021/acs.nanolett.5b02582 · DOI
  45. 10.1016/j.tsf.2003.11.242 · DOI
  46. 10.1038/nmat2490 · DOI

Cited by

Sorted by citations

Metadata

Authors
Ge, Y., Liu, J., Liu, X., Hu, J., Duan, X., & Duan, X.
Affiliations
  • Hunan University (CN)
  • University of California, Los Angeles (US)
Corresponding author
  • Hu, Jiawen
  • Duan, Xidong
  • Duan, Xiangfeng
Venue
Journal of the American Chemical Society
Published
2019-07-30
Volume
141
Issue
31
Pages
12251-12257
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W2964943205
Cited by
61
References
0
Citations by year
2026: 3 · 2025: 10 · 2024: 11 · 2023: 5 · 2022: 10 · 2021: 17 · 2020: 5
FWCI
2.88
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the American Chemical Society (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Hunan University
  • China Scholarship Council
  • National Natural Science Foundation of China (21673070, 21872047)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
silver nanowires, electrochemical cleaning, transparent conductors, sheet resistance, carrier transport, hydrogen adsorption, interfacial resistance, wearable strain sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review