The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Impact of Antifouling PEG Layer on the Performance of Functional Peptides in Regulating Cell Behaviors
Abstract
Cell adhesive and other functional peptides (such as RGD, KRSR, YIGSR, VAPG, and BMP-2 peptides) are extensively studied and utilized in tissue engineering scaffolds and biomedical devices to modulate cell functions. Though PEG is frequently used as the antifouling layer, it is unclear how it affects the performance of functional peptides. By analyzing the impact of PEG at short (OEG4), medium (OEG8), and long chain length (PEG2K), we reveal that PEG chain length is critical and a medium-length PEG enables functional peptides to display their optimal and genuine functions in cell adhesion, migration, and differentiation by providing excellent antifouling to minimize background noise of unwanted cell adhesion and high enough surface density of functional peptides. Our result provides new avenues for maximizing the genuine functions of peptides. This study also provides a solution to prevent the heterogeneous and even divergent results caused by inappropriate choice of antifouling PEG and provides a general guidance in identifying new functional peptides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Cited by
Surface Design for Antibacterial Materials: From Fundamentals to Advanced Strategies
Li, W., Thian, E. S., Wang, M., Wang, Z., & Ren, L. (2021) · Advanced Science · doi:10.1002/advs.202100368 · Cited by 429
Wound management materials and technologies from bench to bedside and beyond
Wang, C., Shirzaei Sani, E., Shih, C.-D., Lim, C. T., Wang, J., Armstrong, D. G., & Gao, W. (2024) · Nature Reviews Materials · doi:10.1038/s41578-024-00693-y · Cited by 396
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
Self-citationAntifouling graphene oxide membranes for oil-water separation via hydrophobic chain engineering
Yang, C., Long, M., Ding, C., Zhang, R., Zhang, S., Yuan, J., Zhi, K., Yin, Z., Zheng, Y., Liu, Y., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-35105-8 · Cited by 273
Metadata
- Authors
- Chen, Q., Yu, S., Zhang, D., Zhang, W., Zhang, H., Zou, J., Mao, Z., Yuan, Y., Gao, C., & Liu, R.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-10-01
- Volume
- 141
- Issue
- 42
- Pages
- 16772-16780
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2977948085
- Cited by
- 219
- References
- 1
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.