The DOI matches its Crossref record.
The Application of Biosensors to Fresh Produce and the Wider Food Industry
Abstract
The inherent specificity, selectivity, and adaptability of biosensors make them ideal candidates for use throughout the food industry. Potential applications within the supply chain range from testing of foodstuffs for maximum pesticide residue verification through to the routine analysis of analyte(s) concentrations, such as, glucose, sucrose, alcohol, etc., which may be indicators of food quality/acceptability. Biosensor formats include simple "one-shot" disposable devices that can be used either in the field or integrated into more sophisticated laboratory instruments. Until now, the main impact of these devices has been in the medical diagnostics field. However, with ongoing technical development, the food industry will be one of the prime beneficiaries of biosensor technology in the future. This report assesses the current and future trends in the application of biosensors to fresh produce and the wider food industry, focusing on both potential and current target analytes that are fundamental to fresh produce quality, traceability, and safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microbial lipases and their industrial applications: a comprehensive review
Chandra, P., Enespa, Singh, R., & Arora, P. K. (2020) · Microbial Cell Factories · doi:10.1186/s12934-020-01428-8 · Cited by 887
Glucose oxidase: natural occurrence, function, properties and industrial applications
Wong, C. M., Wong, K. H., & Chen, X. D. (2008) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-008-1407-4 · Cited by 553
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Noble metal nanoparticles in biosensors: recent studies and applications
Malekzad, H., Sahandi Zangabad, P., Mirshekari, H., Karimi, M., & Hamblin, M. R. (2017) · Nanotechnology Reviews · doi:10.1515/ntrev-2016-0014 · Cited by 375
Prospects of conducting polymers in biosensors
Malhotra, B. D., Chaubey, A., & Singh, S. P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.055 · Cited by 372
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
Triboelectric Nanogenerator‐Based Sensor Systems for Chemical or Biological Detection
Zhou, Q., Pan, J., Deng, S., Xia, F., & Kim, T. (2021) · Advanced Materials · doi:10.1002/adma.202008276 · Cited by 259
Chen, T.-W., Ramachandran, R., Chen, S.-M., Anushya, G., & Ramachandran, K. (2020) · Sensors · doi:10.3390/s20236755 · Cited by 37
Metadata
- Authors
- Terry, L. A., White, S. F., & Tigwell, L. J.
- Venue
- Journal of Agricultural and Food Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-03
- Volume
- 53
- Issue
- 5
- Pages
- 1309-1316
- ISSN
- 0021-8561 (ISSN-L)
- 1520-5118
- OpenAlex
- W1998758916
- Cited by
- 287
- References
- 0
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.