The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Effective Adsorption of Heavy Metal Ions from Aqueous Solutions by Macroporous Xylan-Rich Hemicelluloses-Based Hydrogel
Abstract
Xylan-rich hemicelluloses-based hydrogel was developed as a novel porous bioadsorbent by graft co-polymerization of acrylic acid (AA) and xylan-rich hemicelluloses for adsorption of heavy metal ions (Pd(2+), Cd(2+), and Zn(2+)) from aqueous solutions. The chemical structure, the interaction between the hydrogel and metal ions, and the porous structure of xylan-rich hemicelluloses-g-AA hydrogel were revealed by Fourier transform infrared spectroscopy and scanning electron microscopy. The effects of AA and cross-linker dosage, pH value, contacting time, and initial concentration of metal ion on the adsorption capacity were studied. The adsorption equilibrium time was about 60 min from the adsorption kinetics study. The maximum adsorption capacities of Pd(2+), Cd(2+), and Zn(2+) were 859, 495, and 274 mg/g, respectively. Furthermore, xylan-rich hemicelluloses-g-AA hydrogel also exhibited highly efficient regeneration and metal ion recovery efficiency and can be reused without noticeable loss of adsorption capacity for Pd(2+), Cd(2+), and Zn(2+) after quite a number of repeated adsorption/desorption cycles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Removal of Heavy Metals by Waste Tea Leaves from Aqueous Solution
Ahluwalia, S. S., & Goyal, D. (2005) · Engineering in Life Sciences · doi:10.1002/elsc.200420066 · Cited by 374
Cited by
Removal of heavy metal ions from aqueous system by ion-exchange and biosorption methods
Bashir, A., Malik, L. A., Ahad, S., Manzoor, T., Bhat, M. A., Dar, G. N., & Pandith, A. H. (2019) · Environmental Chemistry Letters · doi:10.1007/s10311-018-00828-y · Cited by 737
Hydrogels based on cellulose and chitin: fabrication, properties, and applications
Shen, X., Shamshina, J. L., Berton, P., Gurau, G., & Rogers, R. D. (2016) · Green Chemistry · doi:10.1039/c5gc02396c · Cited by 669
Chen, Q., Zhu, L., Chen, H., Yan, H., Huang, L., Yang, J., & Zheng, J. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201404357 · Cited by 632
Raji, Z., Karim, A., Karam, A., & Khalloufi, S. (2023) · Waste · doi:10.3390/waste1030046 · Cited by 517
Hemicellulose: Structure, chemical modification, and application
Rao, J., Lv, Z., Chen, G., & Peng, F. (2023) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2023.101675 · Cited by 508
Metadata
- Authors
- Peng, X.-W., Zhong, L.-X., Ren, J.-L., & Sun, R.-C.
- Venue
- Journal of Agricultural and Food Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-06
- Volume
- 60
- Issue
- 15
- Pages
- 3909-3916
- ISSN
- 0021-8561 (ISSN-L)
- 1520-5118
- OpenAlex
- W2058062237
- Cited by
- 230
- References
- 1
- FWCI
- 15.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.