Requirements for Specific Binding of Low Affinity Inhibitor Fragments to the SH2 Domain ofpp60Src Are Identical to Those for High Affinity Binding of Full Length Inhibitors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Results from a novel approach which uses protein crystallography for the screening of a low affinity inhibitor fragment library are analyzed by comparing the X-ray structures with bound fragments to the structures with the corresponding full length inhibitors. The screen for new phospho-tyrosine mimics binding to the SH2 domain of (pp60)src was initiated because of the limited cell penetration of phosphates. Fragments in our library typically had between 6 and 30 atoms and included compounds which had either millimolar activity in a Biacore assay or were suggested by the ab initio design program LUDI but had no measurable affinity. All identified fragments were located in the phospho-tyrosine pocket. The most promising fragments were successfully used to replace the phospho-tyrosine and resulted in novel nonpeptidic high affinity inhibitors. The significant diversity of successful fragments is reflected in the high flexibility of the phospho-tyrosine pocket. Comparison of the X-ray structures shows that the presence of the H-bond acceptors and not their relative position within the pharmacophore are essential for fragment binding and/or high affinity binding of full length inhibitors. The X-ray data show that the fragments are recognized by forming a complex H-bond network within the phospho-tyrosine pocket of SH2. No fragment structure was found in which this H-bond network was incomplete, and any uncompensated H-bond within the H-bond network leads to a significant decrease in the affinity of full length inhibitors. No correlation between affinity and fragment binding was found for these polar fragments and hence affinity-based screening would have overlooked some interesting starting points for inhibitor design. In contrast, we were unable to identify electron density for hydrophobic fragments, confirming that hydrophobic interactions are important for inhibitor affinity but of minor importance for ligand recognition. Our results suggest that a screening approach using protein crystallography is particularly useful to identify universal fragments for the conserved hydrophilic recognition sites found in target families such as SH2 domains, phosphatases, kinases, proteases, and esterases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kelly, M. A., Liang, H., Sytwu, I.-I., Vlattas, I., Lyons, N. L., Bowen, B. R., & Wennogle, L. P. (1996) · Biochemistry · doi:10.1021/bi960571x · Cited by 63
Cited by
A decade of fragment-based drug design: strategic advances and lessons learned
Hajduk, P. J., & Greer, J. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2220 · Cited by 1,064
Rees, D. C., Congreve, Murray, C. W., & Carr, R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1467 · Cited by 798
Erlanson, D. A., McDowell, R. S., & O'Brien, T. (2004) · Journal of Medicinal Chemistry · doi:10.1021/jm040031v · Cited by 642
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Fragment-Based Lead Discovery Using X-ray Crystallography
Hartshorn, M. J., Murray, C. W., Cleasby, A., Frederickson, M., Tickle, I. J., & Jhoti, H. (2005) · Journal of Medicinal Chemistry · doi:10.1021/jm0495778 · Cited by 422
Metadata
- Authors
- Lange, G., Lesuisse, D., Deprez, P., Schoot, B., Loenze, P., Bénard, D., Marquette, J.-P., Broto, P., Sarubbi, E., & Mandine, E.
- Venue
- Journal of Medicinal Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-10-28
- Volume
- 46
- Issue
- 24
- Pages
- 5184-5195
- ISSN
- 0022-2623 (ISSN-L)
- 1520-4804
- OpenAlex
- W2086679478
- Cited by
- 55
- References
- 1
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.