The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Assessing Scoring Functions for Protein−Ligand Interactions
Abstract
An assessment of nine scoring functions commonly applied in docking using a set of 189 protein-ligand complexes is presented. The scoring functions include the CHARMm potential, the scoring function DrugScore, the scoring function used in AutoDock, the three scoring functions implemented in DOCK, as well as three scoring functions implemented in the CScore module in SYBYL (PMF, Gold, ChemScore). We evaluated the abilities of these scoring functions to recognize near-native configurations among a set of decoys and to rank binding affinities. Binding site decoys were generated by molecular dynamics with restraints. To investigate whether the scoring functions can also be applied for binding site detection, decoys on the protein surface were generated. The influence of the assignment of protonation states was probed by either assigning "standard" protonation states to binding site residues or adjusting protonation states according to experimental evidence. The role of solvation models in conjunction with CHARMm was explored in detail. These include a distance-dependent dielectric function, a generalized Born model, and the Poisson equation. We evaluated the effect of using a rigid receptor on the outcome of docking by generating all-pairs decoys ("cross-decoys") for six trypsin and seven HIV-1 protease complexes. The scoring functions perform well to discriminate near-native from misdocked conformations, with CHARMm, DOCK-energy, DrugScore, ChemScore, and AutoDock yielding recognition rates of around 80%. Significant degradation in performance is observed in going from decoy to cross-decoy recognition for CHARMm in the case of HIV-1 protease, whereas DrugScore and ChemScore, as well as CHARMm in the case of trypsin, show only small deterioration. In contrast, the prediction of binding affinities remains problematic for all of the scoring functions. ChemScore gives the highest correlation value with R(2) = 0.51 for the set of 189 complexes and R(2) = 0.43 for the set of 116 complexes that does not contain any of the complexes used to calibrate this scoring function. Neither a more accurate treatment of solvation nor a more sophisticated charge model for zinc improves the quality of the results. Improved modeling of the protonation states, however, leads to a better prediction of binding affinities in the case of the generalized Born and the Poisson continuum models used in conjunction with the CHARMm force field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development and validation of a genetic algorithm for flexible docking 1 1Edited by F. E. Cohen
Jones, G., Willett, P., Glen, R. C., Leach, A. R., & Taylor, R. (1997) · Journal of Molecular Biology · doi:10.1006/jmbi.1996.0897 · Cited by 6,763
Comparative evaluation of 11 scoring functions for molecular docking.
Wang, R., Lu, Y., & Wang, S. (2003) · Journal of Medicinal Chemistry · doi:10.1021/jm0203783 · Cited by 849
Bissantz, C., Folkers, G., & Rognan, D. (2000) · Journal of Medicinal Chemistry · doi:10.1021/jm001044l · Cited by 740
Charifson, P. S., Corkery, J. J., Murcko, M. A., & Walters, W. P. (1999) · Journal of Medicinal Chemistry · doi:10.1021/jm990352k · Cited by 698
Folding funnels, binding funnels, and protein function
Tsai, C., Kumar, S., Ma, B., & Nussinov, R. (1999) · Protein Science · doi:10.1110/ps.8.6.1181 · Cited by 648
A model binding site for testing scoring functions in molecular docking.
Wei, B. Q., Baase, W. A., Weaver, L. H., Matthews, B. W., & Shoichet, B. K. (2002) · Journal of Molecular Biology · doi:10.1016/s0022-2836(02)00777-5 · Cited by 237
Cited by
Directory of useful decoys, enhanced (DUD-E): better ligands and decoys for better benchmarking.
Mysinger, M. M., Carchia, M., Irwin, J. J., & Shoichet, B. K. (2012) · Journal of Medicinal Chemistry · doi:10.1021/jm300687e · Cited by 2,412
SwissParam: A fast force field generation tool for small organic molecules
Zoete, V., Cuendet, M. A., Grosdidier, A., & Michielin, O. (2011) · Journal of Computational Chemistry · doi:10.1002/jcc.21816 · Cited by 2,370
Benchmarking sets for molecular docking.
Huang, N., Shoichet, B. K., & Irwin, J. J. (2006) · Journal of Medicinal Chemistry · doi:10.1021/jm0608356 · Cited by 1,318
Evaluating Virtual Screening Methods: Good and Bad Metrics for the “Early Recognition” Problem
Truchon, J.-F., & Bayly, C. I. (2007) · Journal of Chemical Information and Modeling · doi:10.1021/ci600426e · Cited by 874
Moitessier, N., Englebienne, P., Lee, D., Lawandi, J., & Corbeil, C. R. (2008) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0707515 · Cited by 514
Metadata
- Authors
- Ferrara, P., Gohlke, H., Price, D. J., Klebe, G., & Brooks, C. L.
- Venue
- Journal of Medicinal Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-05-04
- Volume
- 47
- Issue
- 12
- Pages
- 3032-3047
- ISSN
- 0022-2623 (ISSN-L)
- 1520-4804
- OpenAlex
- W2098971704
- Cited by
- 481
- References
- 6
- FWCI
- 40.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.