The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Radiohalogenated Prostate-Specific Membrane Antigen (PSMA)-Based Ureas as Imaging Agents for Prostate Cancer
Open accessAbstract
To extend our development of new imaging agents targeting the prostate-specific membrane antigen (PSMA), we have used the versatile intermediate 2-[3-(5-amino-1-carboxy-pentyl)-ureido]-pentanedioic acid (Lys-C(O)-Glu), which allows ready incorporation of radiohalogens for single photon emission computed tomography (SPECT) and positron emission tomography (PET). We prepared 2-[3-[1-carboxy-5-(4-[(125)I]iodo-benzoylamino)-pentyl]-ureido]-pentanedioic acid ([(125)I]3), 2-[3-[1-carboxy-5-(4-[(18)F]fluoro-benzoylamino)-pentyl]-ureido]-pentanedioic acid ([(18)F]6), and 2-(3-[1-carboxy-5-[(5-[(125)I]iodo-pyridine-3-carbonyl)-amino]-pentyl]-ureido)-pentanedioic acid ([(125)I]8) in 65-80% (nondecay-corrected), 30-35% (decay corrected), and 59-75% (nondecay-corrected) radiochemical yields. Compound [(125)I]3 demonstrated 8.8 +/- 4.7% injected dose per gram (%ID/g) within PSMA(+) PC-3 PIP tumor at 30 min postinjection, which persisted, with clear delineation of the tumor by SPECT. Similar tumor uptake values at early time points were demonstrated for [(18)F]6 (using PET) and [(125)I]8. Because of the many radiohalogenated moieties that can be attached via the epsilon amino group, the intermediate Lys-C(O)-Glu is an attractive template upon which to develop new imaging agents for prostate cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crystal structure of prostate-specific membrane antigen, a tumor marker and peptidase
Davis, M. I., Bennett, M. J., Thomas, L. M., & Bjorkman, P. J. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502101102 · Cited by 296
Cited by
68Ga-Complex Lipophilicity and the Targeting Property of a Urea-Based PSMA Inhibitor for PET Imaging
Eder, M., Schäfer, M., Bauder-Wüst, U., Hull, W.-E., Wängler, C., Mier, W., Haberkorn, U., & Eisenhut, M. (2012) · Bioconjugate Chemistry · doi:10.1021/bc200279b · Cited by 843
Mechanisms of drug release in nanotherapeutic delivery systems
Wong, P. T., & Choi, S. K. (2015) · Chemical Reviews · doi:10.1021/cr5004634 · Cited by 507
Chen, Y., Pullambhatla, M., Foss, C. A., Byun, Y., Nimmagadda, S., Senthamizhchelvan, S., Sgouros, G., Mease, R. C., & Pomper, M. G. (2011) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-11-1357 · Cited by 388
Self-citationEder, M., Neels, O., Müller, M., Bauder-Wüst, U., Remde, Y., Schäfer, M., Hennrich, U., Eisenhut, M., Afshar-Oromieh, A., Haberkorn, U., et al. (2014) · Pharmaceuticals · doi:10.3390/ph7070779 · Cited by 370
Hillier, S. M., Maresca, K. P., Femia, F. J., Marquis, J. C., Foss, C. A., Nguyen, N., Zimmerman, C. N., Barrett, J. A., Eckelman, W. C., Pomper, M. G., et al. (2009) · Cancer Research · doi:10.1158/0008-5472.can-09-1682 · Cited by 316
Self-citation
Metadata
- Authors
- Chen, Y., Foss, C. A., Byun, Y., Nimmagadda, S., Pullambhatla, M., Fox, J. J., Castanares, M., Lupold, S. E., Babich, J. W., Mease, R. C., & Pomper, M. G.
- Venue
- Journal of Medicinal Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-12-03
- Volume
- 51
- Issue
- 24
- Pages
- 7933-7943
- ISSN
- 0022-2623 (ISSN-L)
- 1520-4804
- OpenAlex
- W1973269553
- Cited by
- 190
- References
- 1
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.