The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Fluorescent Tris-Imidazolium Sensors for Picric Acid Explosive
Abstract
Two new anthracene-functionalized fluorescent tris-imidazolium salts have been synthesized, characterized, and proven to be selective sensors for picric acid, which is a common constituent of many powerful explosives. Theoretical studies revealed an unusual ground-state electron transfer from picrate anion to the sensor molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemical Sensors Based on Amplifying Fluorescent Conjugated Polymers
Thomas, S. W., Joly, G. D., & Swager, T. M. (2007) · Chemical Reviews · doi:10.1021/cr0501339 · Cited by 4,198
Pramanik, S., Zheng, C., Zhang, X., Emge, T. J., & Li, J. (2011) · Journal of the American Chemical Society · doi:10.1021/ja106851d · Cited by 1,137
Optical explosives detection: from color changes to fluorescence turn-on
Germain, M. E., & Knapp, M. J. (2009) · Chemical Society Reviews · doi:10.1039/b809631g · Cited by 1,046
Polymer sensors for nitroaromatic explosives detection
Toal, S. J., & Trogler, W. C. (2006) · Journal of Materials Chemistry · doi:10.1039/b517953j · Cited by 998
Instrumentation for trace detection of high explosives
Moore, D. S. (2004) · Review of Scientific Instruments · doi:10.1063/1.1771493 · Cited by 812
The Medicinal Applications of Imidazolium Carbene−Metal Complexes
Hindi, K. M., Panzner, M. J., Tessier, C. A., Cannon, C. L., & Youngs, W. J. (2009) · Chemical Reviews · doi:10.1021/cr800500u · Cited by 776
Akhavan, J. (2022) · Royal Society of Chemistry eBooks · doi:10.1039/9781839168802 · Cited by 690
Xu, Z., Kim, S. K., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b918937h · Cited by 531
Attogram Sensing of Trinitrotoluene with a Self-Assembled Molecular Gelator
Kartha, K. K., Babu, S. S., Srinivasan, S., & Ajayaghosh, A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja210728c · Cited by 486
EXPLOSIVES DETECTION: A Challenge for Physical Chemistry
Steinfeld, J. I., & Wormhoudt, J. (1998) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.49.1.203 · Cited by 413
Cited by
Fluorescence based explosive detection: from mechanisms to sensory materials
Sun, X., Wang, Y., & Lei, Y. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00496a · Cited by 1,243
Wang, Y., & Ni, Y. (2014) · Analytical Chemistry · doi:10.1021/ac5012014 · Cited by 422
A fluorescent organic cage for picric acid detection
Acharyya, K., & Mukherjee, P. S. (2014) · Chem. Commun. · doi:10.1039/c4cc06225f · Cited by 267
Self-citation
Metadata
- Authors
- Roy, B., Bar, A. K., Gole, B., & Mukherjee, P. S.
- Venue
- The Journal of Organic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-23
- Volume
- 78
- Issue
- 3
- Pages
- 1306-1310
- ISSN
- 0022-3263 (ISSN-L)
- 1520-6904
- OpenAlex
- W2313647659
- Cited by
- 278
- References
- 19
- FWCI
- 15.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent Tris-Imidazolium Sensors for Picric Acid Explosive. https://app.cochat.ai/papers/10.1021/jo302585a
- The paper
- Roy, B., Bar, A. K., Gole, B., & Mukherjee, P. S. (2013). Fluorescent Tris-Imidazolium Sensors for Picric Acid Explosive. The Journal of Organic Chemistry. https://doi.org/10.1021/jo302585a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.