The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Ion Sieving Effects in the Electrical Double Layer of Porous Carbon Electrodes: Estimating Effective Ion Size in Electrolytic Solutions
Abstract
Certain microporous carbons have pores of molecular dimensions, the size of which can be adjusted over a wide range to fit the dimensions of a large variety of molecules. With knowing the dimensions of these molecules, size-calibrated porous carbons can be produced. In this work, we took advantage of the electronic conductivity of carbon in using it as an electrode in electrolytic solutions. By changing the electrode potential, we could induce electroadsorption and electrodesorption of ions of different dimensions into pore-calibrated carbons, thus enabling us to estimate effective ion sizes. A few fundamental questions such as whether ions accommodated in the electrodes' pores are in a solvated state, which is important for novel electrochemical energy storage devices and for microbiological systems, could be addressed. Analysis of the results indicates that all the cations that are employed are electroadsorbed in the electrode pores in hydrated states. Compared with the monovalent cations, the bivalent cations exhibit dimensions that make them almost twice as big. Monovalent anions are basically adsorbed in a nonhydrated state. The doubly charged sulfate anion is adsorbed in the hydrated state. The nitrate, a multiatom planar anion, has a smaller effective dimension than the monoatomic halogen anions, in accordance with the observation that the pores in many activated carbons are slit-shaped. The analysis of the results enabled us to establish a scale of ionic effective dimensions in aqueous media, as presented below (MTBE stands for methyl tert -butyl ether): cations, [3.62 Å, N 2 ] < Cs + < K + < Na + < Li + < [4.21 Å, CF 4 ] < [5.05 Å, SF 6 ] < [5.8 Å, MTBE] < Ba 2+, Ca 2+, and Mg 2+; anions, [3.62 Å, N 2 ] < NO 3 - < Cl - < F - < Br - < [4.21 Å, CF 4 ] < ClO 4 - < [5.05 Å, SF 6 ] < [5.8 Å, MTBE] < SO 2- . We discovered that as long as the pore size is considerably greater than the ion size, the electric double-layer capacity at moderate concentrations is independent of both the size and charge of the ions in solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption of Gases in Multimolecular Layers
Brunauer, S., Emmett, P. H., & Teller, E. (1938) · Journal of the American Chemical Society · doi:10.1021/ja01269a023 · Cited by 28,156
Intermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Carbon Electrodes for Double-Layer Capacitors I. Relations Between Ion and Pore Dimensions
Salitra, G., Soffer, A., Eliad, L., Cohen, Y., & Aurbach, D. (2000) · Journal of The Electrochemical Society · doi:10.1149/1.1393557 · Cited by 565
Self-citationKoresh, J. E., & Sofer, A. (1983) · Separation Science and Technology · doi:10.1080/01496398308068576 · Cited by 269
Lithium ion batteries : fundamentals and performance
脇原, 将., & 山本, 治. (1998) · Medical Entomology and Zoology · Cited by 258
Water desalting by means of electrochemical parametric pumping
Oren, Y., & Soffer, A. (1983) · Journal of Applied Electrochemistry · doi:10.1007/bf00617522 · Cited by 87
Self-citation
Cited by
Carbons and Electrolytes for Advanced Supercapacitors
Béguin, F., Presser, V., Balducci, A., & Frackowiak, E. (2014) · Advanced Materials · doi:10.1002/adma.201304137 · Cited by 2,686
Efficient storage mechanisms for building better supercapacitors
Salanne, M., Rotenberg, B., Naoi, K., Kaneko, K., Taberna, P.-L., Grey, C. P., Dunn, B., & Simon, P. (2016) · Nature Energy · doi:10.1038/nenergy.2016.70 · Cited by 2,181
Wang, Q., Yan, J., & Fan, Z. (2016) · Energy & Environmental Science · doi:10.1039/c5ee03109e · Cited by 1,225
Templated nanocarbons for energy storage
Nishihara, H., & Kyotani, T. (2012) · Advanced Materials · doi:10.1002/adma.201201715 · Cited by 745
Li, Z., Zhang, L., Amirkhiz, B. S., Tan, X., Xu, Z., Wang, H., Olsen, B. C., Holt, C. M. B., & Mitlin, D. (2012) · Advanced Energy Materials · doi:10.1002/aenm.201100548 · Cited by 649
Metadata
- Authors
- Eliad, L., Salitra, G., Soffer, A., & Aurbach, D.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-06-28
- Volume
- 105
- Issue
- 29
- Pages
- 6880-6887
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W1975239572
- Cited by
- 388
- References
- 6
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ion Sieving Effects in the Electrical Double Layer of Porous Carbon Electrodes: Estimating Effective Ion Size in Electrolytic Solutions. https://app.cochat.ai/papers/10.1021/jp010086y
- The paper
- Eliad, L., Salitra, G., Soffer, A., & Aurbach, D. (2001). Ion Sieving Effects in the Electrical Double Layer of Porous Carbon Electrodes: Estimating Effective Ion Size in Electrolytic Solutions. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp010086y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.