Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record.

Stabilizing Effects of Various Polyelectrolyte Multilayer Films on the Structure of Adsorbed/Embedded Fibrinogen Molecules: An ATR−FTIR Study

Schwinté, P., Voegel, J.-C., Picart, C., Haikel, Y., Schaaf, P., Szalontai, B.·2001·The Journal of Physical Chemistry B

Abstract

The structural changes in fibrinogen as a consequence of its adsorption onto the surface of or its embedding into the interior of poly(allylamine hydrochloride) (PAH) or poly(styrenesulfonate) (PSS) multilayers are investigated by means of attenuated total reflection Fourier transform infrared (ATR−FTIR) spectroscopy. It is found that both adsorption and embedding preserve the secondary structure of the fibrinogen molecules. Furthermore, the interactions of the polyelectrolytes with the protein molecules prevent their aggregation, especially in the embedded state, at room temperature. Thus, it seems that the structure and the biological activity of proteins adsorbed on or embedded in polyelectrolyte multilayers could largely be preserved, which opens up great perspectives in the design of new bioactive surfaces. The nature and the extent of the polyelectrolyte−protein interactions are further studied via analysis of the thermotropic responses of the different architectures. It is found that both PAH- and PSS-terminated polyelectrolyte multilayers can elevate the onset temperature of the structural changes in adsorbed/embedded fibrinogen molecules by about 5 °C as compared with that for fibrinogen in solution. These polyelectrolytes also broaden the thermally induced structural transitions in the adsorbed/embedded fibrinogen molecules. The magnitude of these thermally induced structural changes is polyelectrolyte- and architecture-dependent. Whereas multilayer PAH−fibrinogen and multilayer PSS−fibrinogen constructions exhibit roughly the same large-scale thermally induced structural changes, in all architectures where fibrinogen is embedded the scale of these structural changes is restricted. The restriction becomes stronger as the presence of PSS at the polyelectrolyte−fibrinogen interfaces increases (PAH−fib−PAH < PAH−fib−PSS ≈ PSS−fib−PAH < PSS−fib−PSS). In the PSS−fib−PSS arrangement, the secondary structure of fibrinogen as determined from its infrared spectrum changes only slightly up to 90 °C. The underlying processes of the thermally induced structural changes is, in addition, different for fibrinogen molecules adsorbed onto or embedded into PAH-terminated polyelectrolyte multilayers. A tentative model based on “encapsulation” of the embedded protein by the polyelectrolytes is proposed to explain the observed features.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp0123031

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Schwinté, P., Voegel, J.-C., Picart, C., Haikel, Y., Schaaf, P., & Szalontai, B.
Venue
The Journal of Physical Chemistry B
Published
2001-09-25
Volume
105
Issue
47
Pages
11906-11916
ISSN
  • 1520-5207 (ISSN-L)
  • 1520-6106
OpenAlex
W2057678070
Cited by
186
References
0
FWCI
8.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stabilizing Effects of Various Polyelectrolyte Multilayer Films on the Structure of Adsorbed/Embedded Fibrinogen Molecules: An ATR−FTIR Study. https://app.cochat.ai/papers/10.1021/jp0123031
The paper
Schwinté, P., Voegel, J.-C., Picart, C., Haikel, Y., Schaaf, P., & Szalontai, B. (2001). Stabilizing Effects of Various Polyelectrolyte Multilayer Films on the Structure of Adsorbed/Embedded Fibrinogen Molecules: An ATR−FTIR Study. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp0123031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.