Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record.

The Relaxation Pathways of CdSe Nanoparticles Monitored with Femtosecond Time-Resolution from the Visible to the IR: Assignment of the Transient Features by Carrier Quenching

Burda, Clemens, Link, Stephan, Mohamed, Mona, El-Sayed, Mostafa·2001·The Journal of Physical Chemistry B

Abstract

The relaxation dynamics of photoexcited CdSe nanoparticles (NPs) were studied with femtosecond pump−probe spectroscopy in the spectral range from 450 nm to 5 μm. Thus, the intraband relaxation of the electron and the hole were monitored with femtosecond time resolution. The transition from delocalized electronic to localized defect states and the slower relaxation through the trapping sites (trap hopping mechanism) were followed by time-resolved emission on time scales from picoseconds to milliseconds in the spectral range from the visible into the mid-infrared. The spectral dynamics in the visible, near-infrared (NIR), and infrared (IR) range give a mechanistic picture about the relaxation pathway of the excited charge carriers in CdSe NPs. In addition, by using electron and hole quenchers to the photoexcited nanoparticles, we could assign the observed dynamics to the electron or the hole. In the visible range, bleach features (negative signals in the differential transient absorption measurements) were observed at early delay times with time components of 2 ps, 30 ps, and a long-lived component of ∼200 ps. Based on the quenching experiments, the bleach could be assigned to contributions from the electron and the hole. In the NIR and IR spectral range, the transient signal for short delay times (<1 ns) were positive (transient absorption). A decay time of 1.2 ps was found for the transient absorption observed in the NIR. With the carrier removal technique, it could be shown that the NIR signal is mainly due to hole transitions. The IR signal with lifetimes of 2 ps, 30 ps, and a long component of ∼200 ps compares directly to the decay times observed in the visible spectral range. It therefore is also composed of contributions from electron and hole. Photoluminescence is observed in the visible range at 570 nm (near band edge recombination), in the NIR at 1000 nm (deep-trap emission), and in the IR region at 4.8 μm (deeper-trap emission) with lifetimes of 43 ns, 250 ns, and 1 μs, respectively. The lifetimes of the emission increased for longer monitoring wavelengths, suggesting that for the investigated sample, the carriers relax from the band edge into shallow traps and from there continue stepwise relaxation into lower energy sites (trap hopping mechanism).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp0124589

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Burda, C., Link, S., Mohamed, M., & El-Sayed, M.
Venue
The Journal of Physical Chemistry B
Published
2001-11-08
Volume
105
Issue
49
Pages
12286-12292
ISSN
  • 1520-5207 (ISSN-L)
  • 1520-6106
OpenAlex
W2016376718
Cited by
230
References
0
FWCI
6.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Relaxation Pathways of CdSe Nanoparticles Monitored with Femtosecond Time-Resolution from the Visible to the IR: Assignment of the Transient Features by Carrier Quenching. https://app.cochat.ai/papers/10.1021/jp0124589
The paper
Burda, C., Link, S., Mohamed, M., & El-Sayed, M. (2001). The Relaxation Pathways of CdSe Nanoparticles Monitored with Femtosecond Time-Resolution from the Visible to the IR: Assignment of the Transient Features by Carrier Quenching. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp0124589

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.