The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Conformational Change of Poly(N-isopropylacrylamide) during the Coil−Globule Transition Investigated by Attenuated Total Reflection/Infrared Spectroscopy and Density Functional Theory Calculation
Abstract
A conformational change in the coil−globule transition of poly( N -isopropylacrylamide) (PNiPA) was investigated by Fourier transform infrared (FT-IR) spectroscopy with attenuated total reflection (ATR) method and density functional theory (DFT) calculations. ATR/IR spectra of PNiPA in an aqueous solution change dramatically in the vicinity of the coil−globule transition temperature (θ temperature). Below the θ temperature, unimodal peaks are observed at 1624 cm -1 in the amide I region and at 1562 cm -1 in the amide II region, respectively. Above the θ temperature, a new peak appears abruptly near 1653 cm -1 in the amide I region and the amide II band shifts gradually to a lower frequency by 6 cm -1 . In the amide III region, the relative intensity of a band at 1173 cm -1 is weaker than that of a band at 1155 cm -1 at lower temperatures, but it becomes larger during the coil−globule transition of PNiPA. DFT calculation for dimer models of PNiPA suggests that the amide I band at 1624 cm -1 is assigned mainly to a stretching vibration of the C═O group that forms a strong hydrogen bond with the N−H bond of a neighboring amide group. The band at 1653 cm -1 observed above the θ temperature may be due to a free C═O group. It is, therefore, suggested that some of the intramolecular hydrogen bonds between neighboring amide groups are broken during the coil−globule transition. Furthermore, it is deduced from the DFT calculation that the relative intensity of the bands at 1173 and 1155 cm -1 in the amide III region reflects the population change in the gauche and trans conformations in the main chain during the coil−globule transition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Cited by
Non-ionic Thermoresponsive Polymers in Water
Aseyev, V., Tenhu, H., & Winnik, F. M. (2010) · Advances in Polymer Science · doi:10.1007/12_2010_57 · Cited by 497
pH‐Triggered Thermally Responsive Polymer Core–Shell Nanoparticles for Drug Delivery
Soppimath, K. S., Tan, D. C. ‐., & Yang, Y. ‐. (2005) · Advanced Materials · doi:10.1002/adma.200401057 · Cited by 390
Multi-Stimuli-Responsive Polymer Particles, Films, and Hydrogels for Drug Delivery
Fu, X., Hosta-Rigau, L., Chandrawati, R., & Cui, J. (2018) · Chem · doi:10.1016/j.chempr.2018.07.002 · Cited by 381
Metadata
- Authors
- Katsumoto, Y., Tanaka, T., Sato, H., & Ozaki, Y.
- Venue
- The Journal of Physical Chemistry A
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-12-14
- Volume
- 106
- Issue
- 14
- Pages
- 3429-3435
- ISSN
- 1089-5639 (ISSN-L)
- 1520-5215
- OpenAlex
- W1964014628
- Cited by
- 240
- References
- 1
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.