Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 355

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Contactless Determination of the Photoconductivity Action Spectrum, Exciton Diffusion Length, and Charge Separation Efficiency in Polythiophene-Sensitized TiO2 Bilayers

Kroeze, Jessica E., Savenije, Tom J., Vermeulen, Martien J. W., Warman, John M.·2003·The Journal of Physical Chemistry B

Abstract

The flash-photolysis time-resolved microwave conductivity technique (FP-TRMC) has been used to study photoinduced charge separation in bilayers consisting of a smooth, transparent, 80 nm thick layer of anatase TiO 2 onto which poly(3-hexylthiophene) (P3HT) sensitizer layers have been spin-coated. Interfacial charge separation, resulting from excitation of the polymer in the visible, is found to persist well into the millisecond time domain. Photoconductivity action spectra have been measured between 420 and 700 nm for P3HT layer thicknesses, L, from ∼2 to 200 nm. Using this electrodeless technique, the bilayers could be irradiated from either the polymer (“front”) or semiconductor (“back”) side. On front-side irradiation at 540 nm (close to the absorption maximum of the polymer), the efficiency of charge separation per incident photon (IPCSE) initially increased to a maximum value of 0.8% for L ≈ 10 nm. For thicker layers the IPCSE gradually decreased, eventually to 0.1% for L ≈ 170 nm. On back-side irradiation the IPCSE increased over the first 10 nm to a value close to the maximum found for front-side irradiation, and decreased only slightly for further increase in layer thickness. Analytical expressions for the thickness dependence based on exciton diffusion with a Lambert−Beer excitation profile have been used to fit the experimental data. Best fits were obtained for an exciton diffusion length, Λ (=√( D τ) with D the diffusion coefficient and τ the natural lifetime), of 5.3 or 2.6 nm depending on whether excitons were taken to be reflected or quenched at the polymer/gas interface, respectively. The IPCSE decreased at high light intensities; an effect that is attributed to the occurrence of exciton−exciton annihilation within the polymer layer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp0217738

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 355

Metadata

Authors
Kroeze, J. E., Savenije, T. J., Vermeulen, M. J. W., & Warman, J. M.
Venue
The Journal of Physical Chemistry B
Published
2003-07-04
Volume
107
Issue
31
Pages
7696-7705
ISSN
  • 1520-5207 (ISSN-L)
  • 1520-6106
OpenAlex
W2045034489
Cited by
355
References
1
FWCI
9.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.