Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Dynamics of Solvation of the Fluorescent State of Some Electron Donor−Acceptor Molecules in Room Temperature Ionic Liquids, [BMIM][(CF3SO2)2N] and [EMIM][(CF3SO2)2N]

Karmakar, Rana, Samanta, Anunay·2003·The Journal of Physical Chemistry A

Abstract

Room temperature ionic liquids, particularly those based on the imidazolium salts, have emerged in recent years as highly promising “green” media suitable for carrying out various reactions. In this paper, picosecond time-resolved fluorescence decay behavior of three electron donor−acceptor (EDA) molecules, coumarin-153 (C153), 6-propionyl-2-dimethylaminonaphthalene (PRODAN), and 4-aminophthalimide (AP), in two room temperature ionic liquids, 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([EMIM][(CF 3 SO 2 ) 2 N]) and 1-butyl-3-methylimidazolium bis(trifluoromethane sulfonyl)imide ([BMIM][(CF 3 SO 2 ) 2 N]), has been reported. The steady-state fluorescence behavior of the EDA molecules suggests that the polarity of the two ionic liquids in the E T (30) scale is around 47.6 for [EMIM][(CF 3 SO 2 ) 2 N] and 47.1 for [BMIM][(CF 3 SO 2 ) 2 N]. The fluorescence decay behavior of the systems in these media has been found to be dependent on the monitoring wavelength, suggesting solvent-induced relaxation of the fluorescent state of the systems in the picosecond time domain. Time-resolved fluorescence spectra of the systems, constructed from the wavelength-dependent decay profiles, show a Stokes shift of the fluorescence maxima with time. The time dependence of the spectral shift of the systems has been quantitatively analyzed to obtain information on the solvation dynamics in these media. The solvation dynamics has been found to be biphasic consisting of a short (∼0.2 ns) and a long component (∼1.0−1.2 ns). The short component has been assigned to the diffusional motion of the anion, while the long component is attributed to the collective motion of the anion and the cation. The average solvation time in the present ionic liquids is found to be faster than that in [BF 4 ] - -based ionic liquids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp030683f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Karmakar, R., & Samanta, A.
Venue
The Journal of Physical Chemistry A
Published
2003-08-19
Volume
107
Issue
38
Pages
7340-7346
ISSN
  • 1089-5639 (ISSN-L)
  • 1520-5215
OpenAlex
W2324501011
Cited by
181
References
1
FWCI
9.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.