The DOI matches its Crossref record.
What Factors Control the Size and Shape of Silver Nanoparticles in the Citrate Ion Reduction Method?
Abstract
Citrate ion, a commonly used reductant in metal colloid synthesis, undergoes strong surface interaction with silver nanocrystallites. The slow crystal growth observed as a result of the interaction between the silver surface and the citrate ion makes this reduction process unique compared to other chemical and radiolytic synthetic methods. Addition of citrate ions to preformed silver colloids (Ag-capped SiO 2 ) results in the complexation of citrate with silver colloids. The difference absorption spectra of SiO 2 −Ag colloids in the presence of citrate ions show an increase in the absorption at 410 nm with increase in concentration of citrate. The apparent association constant as determined from these absorption changes is 220 M -1 . Pulse-radiolysis studies show that citrate ions complex with the silver seeds and influence the particle growth. For example, one of the primary intermediates, Ag 2 + produced in the radiolytic reduction of silver ions, readily interacts with citrate to form a complex absorbing in the 410-nm region. The complex, [Ag 2 + −citrate], undergoes slower transformations compared to uncomplexed Ag 2 + . This slow transformation of the citrate complex eventually leads to the formation of larger clusters of silver. Steady-state and pulse-radiolysis experiments provide evidence for the multiple roles of citrate ions as a reductant, complexant, and stabilizer that collectively dictate the size and shape of silver nanocrystallites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guzman, M., Dille, J., & Godet, S. (2012) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2011.05.007 · Cited by 894
Vanlalveni, C., Lallianrawna, S., Biswas, A., Selvaraj, M., Changmai, B., & Rokhum, S. L. (2021) · RSC Advances · doi:10.1039/d0ra09941d · Cited by 804
Aggregation and Dissolution of Silver Nanoparticles in Natural Surface Water
Li, X., & Lenhart, J. J. (2012) · Environmental Science & Technology · doi:10.1021/es204531y · Cited by 295
Uma Suganya, K. S., Govindaraju, K., Ganesh Kumar, V., Stalin Dhas, T., Karthick, V., Singaravelu, G., & Elanchezhiyan, M. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.11.043 · Cited by 260
Guo, J. W., Zhao, T. S., Prabhuram, J., & Wong, C. W. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.09.006 · Cited by 133
Metadata
- Authors
- Pillai, Z. S., & Kamat, P. V.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-12-19
- Volume
- 108
- Issue
- 3
- Pages
- 945-951
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W1967941611
- Cited by
- 795
- References
- 0
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What Factors Control the Size and Shape of Silver Nanoparticles in the Citrate Ion Reduction Method? https://app.cochat.ai/papers/10.1021/jp037018r
- The paper
- Pillai, Z. S., & Kamat, P. V. (2004). What Factors Control the Size and Shape of Silver Nanoparticles in the Citrate Ion Reduction Method? The Journal of Physical Chemistry B. https://doi.org/10.1021/jp037018r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.