The DOI matches its Crossref record.
Thermal Behavior of Polyelectrolyte Multilayer Microcapsules. 1. The Effect of Odd and Even Layer Number
Abstract
The temperature-dependent behavior of hollow polyelectrolyte multilayer capsules consisting of poly(diallyldimethylammonium chloride) (PDADMAC) and poly(styrene sulfonate) (PSS) with a different number of layers was investigated in aqueous media using confocal laser scanning microscopy, scanning and transmission electron microscopy, atomic force microscopy, and elemental analysis. Capsules with an even number of layers exhibited a pronounced shrinking at elevated temperature resulting in a transition to a dense sphere, whereas capsules with an odd number of layers swelled during heating to 5-fold of their initial size followed by their rupture. This effect increases for odd layer numbers and decreases for even layer numbers with increasing layer number. According to elemental analysis, an excess of PDADMAC monomers exists within the multilayers of capsules with an odd number of layers leading to a repulsion between the positive charges, whereas shells with an even number of layers have a balanced ratio between the oppositely charged polyions, so that the temperature-dependent behavior is controlled by the different interactions between polyelectrolytes and the bulk water. At a certain temperature, the polyelectrolyte material softens thus facilitating any rearrangement. Besides incubation temperature, the duration of heating has an influence on the restructuring of the multilayers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Stimuli-responsive LbL capsules and nanoshells for drug delivery
Delcea, M., Möhwald, H., & Skirtach, A. G. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.010 · Cited by 685
Self-citationRelease mechanisms for polyelectrolyte capsules
De Geest, B. G., Sanders, N. N., Sukhorukov, G. B., Demeester, J., & De Smedt, S. C. (2007) · Chem. Soc. Rev. · doi:10.1039/b600460c · Cited by 462
Self-citationLaser‐Induced Release of Encapsulated Materials inside Living Cells
Skirtach, A. G., Muñoz Javier, A., Kreft, O., Köhler, K., Piera Alberola, A., Möhwald, H., Parak, W. J., & Sukhorukov, G. B. (2006) · Angewandte Chemie · doi:10.1002/ange.200504599 · Cited by 455
Self-citationInternal structure of polyelectrolyte multilayer assemblies
v. Klitzing, R. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b607760a · Cited by 431
Metadata
- Authors
- Köhler, K., Shchukin, D. G., Möhwald, H., & Sukhorukov, G. B.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-09-09
- Volume
- 109
- Issue
- 39
- Pages
- 18250-18259
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2034167881
- Cited by
- 250
- References
- 0
- FWCI
- 10.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal Behavior of Polyelectrolyte Multilayer Microcapsules. 1. The Effect of Odd and Even Layer Number. https://app.cochat.ai/papers/10.1021/jp052208i
- The paper
- Köhler, K., Shchukin, D. G., Möhwald, H., & Sukhorukov, G. B. (2005). Thermal Behavior of Polyelectrolyte Multilayer Microcapsules. 1. The Effect of Odd and Even Layer Number. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp052208i
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.