The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Uncertainties in Scaling Factors for ab Initio Vibrational Frequencies
Abstract
Vibrational frequencies determined from ab initio calculations are often scaled by empirical factors. An empirical scaling factor partially compensates for the errors arising from vibrational anharmonicity and incomplete treatment of electron correlation. These errors are not random but are systematic biases. We report scaling factors for 40 combinations of theory and basis set, intended for predicting the fundamental frequencies from computed harmonic frequencies. An empirical scaling factor carries uncertainty. We quantify and report, for the first time, the uncertainties associated with the scaling factors. The uncertainties are larger than generally acknowledged; the scaling factors have only two significant digits. For example, the scaling factor for HF/6-31G(d) is 0.8982 +/- 0.0230 (standard uncertainty). The uncertainties in the scaling factors lead to corresponding uncertainties in predicted vibrational frequencies. The proposed method for quantifying the uncertainties associated with scaling factors is based on the Guide to the Expression of Uncertainty in Measurement, published by the International Organization for Standardization (ISO). The data used are from the Computational Chemistry Comparison and Benchmark Database (CCCBDB), maintained by the National Institute of Standards and Technology, which includes more than 3939 independent vibrations for 358 molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized Gradient Approximation Made Simple
Perdew, J. P., Burke, K., & Ernzerhof, M. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.3865 · Cited by 215,824
Density-functional exchange-energy approximation with correct asymptotic behavior
Becke, A. D. (1988) · Physical Review A · doi:10.1103/physreva.38.3098 · Cited by 53,711
Accurate and simple analytic representation of the electron-gas correlation energy
Perdew, J. P., & Wang, Y. (1992) · Physical Review B · doi:10.1103/physrevb.45.13244 · Cited by 25,089
General atomic and molecular electronic structure system
Schmidt, M. W., Baldridge, K. K., Boatz, J. A., Elbert, S. T., Gordon, M. S., Jensen, J. H., Koseki, S., Matsunaga, N., Nguyen, K. A., Su, S., et al. (1993) · Journal of Computational Chemistry · doi:10.1002/jcc.540141112 · Cited by 20,204
Molecular Spectra and Molecular Structure
Huber, K. P., & Herzberg, G. (1979) · Springer eBooks · doi:10.1007/978-1-4757-0961-2 · Cited by 16,094
Generalized Gradient Approximation Made Simple [Phys. Rev. Lett. 77, 3865 (1996)]
Perdew, J. P., Burke, K., & Ernzerhof, M. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1396 · Cited by 14,614
Adamo, C., & Barone, V. (1998) · The Journal of Chemical Physics · doi:10.1063/1.475428 · Cited by 3,436
Andersson, M. P., & Uvdal, P. (2005) · The Journal of Physical Chemistry A · doi:10.1021/jp045733a · Cited by 1,659
Pople, J. A., Scott, A. P., Wong, M. W., & Radom, L. (1993) · Israel Journal of Chemistry · doi:10.1002/ijch.199300041 · Cited by 808
Tables of molecular vibrational frequencies
Shimanouchi, T., Matsuura, H., Ogawa, Y., & Harada, I. (1978) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555587 · Cited by 740
Baker, J., Jarzecki, A. A., & Pulay, P. (1998) · The Journal of Physical Chemistry A · doi:10.1021/jp980038m · Cited by 528
Kendall's Advanced Theory of Statistics, Volume 1: Distribution Theory.
Zacks, S., Stuart, A., & Ord, J. K. (1989) · Journal of the American Statistical Association · doi:10.2307/2289685 · Cited by 515
(2000) · Mechanical Testing and Evaluation · doi:10.31399/asm.hb.v08.a0009213 · Cited by 476
Sinha, P., Boesch, S. E., Gu, C., Wheeler, R. A., & Wilson, A. K. (2004) · The Journal of Physical Chemistry A · doi:10.1021/jp048233q · Cited by 471
Halls, M. D., Velkovski, J., & Schlegel, H. B. (2001) · Theoretical Chemistry Accounts · doi:10.1007/s002140000204 · Cited by 460
A priori calculation of molecular properties to chemical accuracy
Helgaker, T., Ruden, T. A., Jørgensen, P., Olsen, J., & Klopper, W. (2004) · Journal of Physical Organic Chemistry · doi:10.1002/poc.841 · Cited by 237
Kacker, R., & Jones, A. (2003) · Metrologia · doi:10.1088/0026-1394/40/5/305 · Cited by 179
Self-citation
Cited by
An Evaluation of Harmonic Vibrational Frequency Scale Factors
Merrick, J. P., Moran, D., & Radom, L. (2007) · The Journal of Physical Chemistry A · doi:10.1021/jp073974n · Cited by 2,735
Alecu, I. M., Zheng, J., Zhao, Y., & Truhlar, D. G. (2010) · Journal of Chemical Theory and Computation · doi:10.1021/ct100326h · Cited by 1,667
Toward control of electron transfer in donor-acceptor molecules by bond-specific infrared excitation
Delor, M., Scattergood, P. A., Sazanovich, I. V., Parker, A. W., Greetham, G. M., Meijer, A. J. H. M., Towrie, M., & Weinstein, J. A. (2014) · Science · doi:10.1126/science.1259995 · Cited by 199
Metadata
- Authors
- Irikura, K. K., Johnson, R. D., & Kacker, R. N.
- Venue
- The Journal of Physical Chemistry A
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-26
- Volume
- 109
- Issue
- 37
- Pages
- 8430-8437
- ISSN
- 1089-5639 (ISSN-L)
- 1520-5215
- OpenAlex
- W2065329544
- Cited by
- 498
- References
- 17
- FWCI
- 15.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.