The DOI matches its Crossref record.
Solubility of CO2in Room Temperature Ionic Liquid [hmim][Tf2N]
Abstract
Solubility measurements of carbon dioxide in 1-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide have been performed with a gravimetric microbalance at temperatures of about 282, 297, 323, and 348 K and pressures up to about 2 MPa. Two different sources for the ionic liquid are examined in this work: an ultrapure sample from NIST (the IUPAC task force sample) and a commercially available sample. Both samples show nearly identical solubility behaviors, being undistinguishable within experimental uncertainties. Solubility (pressure-temperature-composition) data have been well correlated with an equation-of-state (EOS) model used in our previous works. The EOS model calculations are compared with experimental solubility data for the same system in the literature. The present EOS has predicted partial immiscibility at the CO2-rich side solutions. To prove this prediction, vapor-liquid-liquid equilibrium experiments have been made, and our predictions have been confirmed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Improving Carbon Dioxide Solubility in Ionic Liquids
Muldoon, M. J., Aki, S. N. V. K., Anderson, J. L., Dixon, J. K., & Brennecke, J. F. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp071897q · Cited by 800
Carbon dioxide utilization with C–N bond formation: carbon dioxide capture and subsequent conversion
Yang, Z.-Z., He, L.-N., Gao, J., Liu, A.-H., & Yu, B. (2012) · Energy & Environmental Science · doi:10.1039/c2ee02774g · Cited by 520
Physical and Chemical Absorptions of Carbon Dioxide in Room-Temperature Ionic Liquids
Yokozeki, A., Shiflett, M. B., Junk, C. P., Grieco, L. M., & Foo, T. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp805784u · Cited by 462
Self-citationScreening of ionic liquids to capture CO2 by COSMO‐RS and experiments
Zhang, X., Liu, Z., & Wang, W. (2008) · AIChE Journal · doi:10.1002/aic.11573 · Cited by 294
Goodrich, B. F., de la Fuente, J. C., Gurkan, B. E., Lopez, Z. K., Price, E. A., Huang, Y., & Brennecke, J. F. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp2015534 · Cited by 272
Metadata
- Authors
- Shiflett, M. B., & Yokozeki, A.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-01
- Volume
- 111
- Issue
- 8
- Pages
- 2070-2074
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W1999825056
- Cited by
- 258
- References
- 0
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solubility of CO2in Room Temperature Ionic Liquid [hmim][Tf2N]. https://app.cochat.ai/papers/10.1021/jp067627+
- The paper
- Shiflett, M. B., & Yokozeki, A. (2007). Solubility of CO2in Room Temperature Ionic Liquid [hmim][Tf2N]. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp067627%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.