The DOI matches its Crossref record.
Palladium Nanoparticles Decorated Single-Walled Carbon Nanotube Hydrogen Sensor
Abstract
We developed a simple and cost-effective fabrication technique to construct a hydrogen nanosensor by decorating single-walled carbon nanotubes with Pd nanoparticles. By varying the sensor's synthesis conditions (e.g., Pd electrodeposition charge, deposition potential, and initial baseline resistance of the SWNT network), the sensing performance was optimized. The optimized sensor showed excellent sensing properties toward hydrogen (Δ R / R of 0.42%/ppm) with a lower detection limit of 100 ppm and a linear response up to 1000 ppm . The response time decreased from tens of minutes to a few minutes with increasing hydrogen concentration at room temperature. The sensor's recovery time improved under humid air conditions compared to dry air conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Mortazavi, S. Z., Parvin, P., Reyhani, A., Golikand, A. N., & Mirershadi, S. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp1091224 · Cited by 75
Metadata
- Authors
- Mubeen, S., Zhang, T., Yoo, B., Deshusses, M. A., & Myung, N. V.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-04-11
- Volume
- 111
- Issue
- 17
- Pages
- 6321-6327
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2128677782
- Cited by
- 407
- References
- 0
- FWCI
- 21.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.