CoChat

Synthesis, Characterization, and Oxygen Sensing Properties of Functionalized Mesoporous SBA-15 and MCM-41 with a Covalently Linked Ruthenium(II) Complex

Lei, Bingfu, Li, Bin, Zhang, Haoran, Zhang, Liming, Li, Wenlian · 2007 · The Journal of Physical Chemistry C
Cited by 180

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Novel oxygen sensing materials consisting of the [Ru(dpp) 2 Phen] 2+ (dpp = 4, 7-diphenyl-1,10-phenanthroline, Phen = 1,10-phenanthroline) portion covalently grafted to the ordered functionalized mesoporous SBA-15 and MCM-41 backbones are prepared by co-condensation of tetraethoxysilane (TEOS) and the functionalized Ru(II) complex [Ru(dpp) 2 Phen-Si] 2+ (Phen-Si = 2-[4‘-{3-(Triethoxysilyl)propyl}phenyl]imidazo [4,5-f]-1,10-phenanthroline) in the presence of Pluronic P123 or cetyltrimethylammoniumbromide (CTAB) surfactant as template, respectively. 1,10-Phenanthroline covalently grafted to 3-(triethoxysilyl)propyl isocyanate is used not only as the precursors but also as the second ligand of the Ru(dpp) 2 Cl 2 ·2H 2 O complex to prepare the functionalized mesoporous materials for oxygen sensors. For comparative purposes, two different synthesis procedures, including the one-pot synthesis and the postsynthetic treatment methods, are used to prepare the covalently grafted samples. Furthermore, the oxygen sensing materials in which [Ru(dpp) 2 Phen] 2+ is conventionally physically incorporated into the matrix are also prepared. The derivative mesoporous oxygen sensing materials are characterized by Fourier transform infrared (FT-IR), scanning electron microscopy (SEM), small-angle X-ray diffraction, luminescence intensity quenching Stern−Volmer plots, nitrogen adsorption/desorption, elemental analysis, and excited-state decay analysis. The functionalized mesoporous sensing materials appear to be highly sensitive to the O 2 concentration in N 2 . In addition, these mesoporous sensing materials exhibit short response times and can be restored within seconds. The oxygen quenching result shows that the homogeneity and the sensitivity of the covalently assembled samples are superior to those of the physically incorporated ones. Furthermore, a greatly minimized leaching effect of the sensing molecules could be observed in the covalently grafted systems. In addition, the Ru(II)Phen-MCM-41 oxygen sensing materials show an overall increase in luminescent lifetime compared with the Ru(II)Phen-SBA-15 oxygen sensing materials, which is explained in detail by the difference of Ru(II) content and pore structure between the two kinds of mesoporous oxygen sensing materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp070008w

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

Metadata

Authors
Lei, B., Li, B., Zhang, H., Zhang, L., & Li, W.
Venue
The Journal of Physical Chemistry C
Published
2007-07-11
Volume
111
Issue
30
Pages
11291-11301
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2012208195
Cited by
180
References
25
FWCI
4.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.