The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Sensitive and Selective Dopamine Biosensor Fabricated with Silanized Graphene
Abstract
A new type of chemically modified graphene, EDTA-modified reduced graphene (EDTA-RG), was synthesized by silanization of graphene with N -(trimethoxysilylpropyl) ethylenediamine triacetic acid (EDTA-silane). It was found that the presence of EDTA on the graphene surface enables the formation of a very stable suspension of EDTA-RG in Nafion/ethanol solution. When deposited onto a glass carbon electrode surface, a very stable, uniform thin film of EDTA-RG−Nafion composite was successfully obtained. The electrochemical behavior of this EDTA-RG−Nafion modified electrode, electrochemical catalysis, ionic selectivity, and biocompatibility, have been investigated using a variety of electrochemical techniques. The ion selectivity was investigated by using a negatively charged probe [Fe(CN) 6 ] 3−/4−, a positively charged probe, Ru(bpy) 3 2+, and two biomolecules, dopamine and ascorbic acid. The thin film of EDTA-RG−Nafion composite exhibits high ion selectivity. Performances of EDTA−graphene−Nafion modified electrodes toward dopamine were then evaluated. It was found that the chemical modification process introduces carboxylic groups on the edges of graphene and these functional groups, combined with Nafion, provide an appropriate environment for oxidation of dopamine. The oxidation behavior of dopamine shows excellent reversibility in cyclic voltammetry, which was significantly better than that observed at bare GC, Nafion, and Nafion−graphene coated electrodes. In addition, through the combination of the ionic selectivity of sulfuric from Nafion and EDTA groups in graphene, the EDTA-RG−Nafion film can entirely eliminate the interference from the presence of 1000 times ascorbic acid. The new device is an ideal candidate device for the detection of dopamine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dopamine as a Prolactin (PRL) Inhibitor
Ben-Jonathan, N., & Hnasko, R. (2001) · Endocrine Reviews · doi:10.1210/edrv.22.6.0451 · Cited by 983
Cited by
Graphene‐Based Materials: Synthesis, Characterization, Properties, and Applications
Huang, X., Yin, Z., Wu, S., Qi, X., He, Q., Zhang, Q., Yan, Q., Boey, F., & Zhang, H. (2011) · Small · doi:10.1002/smll.201002009 · Cited by 2,569
Biological and chemical sensors based on graphene materials
Liu, Y., Dong, X., & Chen, P. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15270j · Cited by 1,748
Recent advances in graphene-based biosensors
Kuila, T., Bose, S., Khanra, P., Mishra, A. K., Kim, N. H., & Lee, J. H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.039 · Cited by 1,329
Huang, X., Zeng, Z., Fan, Z., Liu, J., & Zhang, H. (2012) · Advanced Materials · doi:10.1002/adma.201201587 · Cited by 923
Adsorption Behavior of EDTA-Graphene Oxide for Pb (II) Removal
Madadrang, C. J., Kim, H. Y., Gao, G., Wang, N., Zhu, J., Feng, H., Gorring, M., Kasner, M. L., & Hou, S. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am201645g · Cited by 844
Self-citation
Metadata
- Authors
- Hou, S., Kasner, M. L., Su, S., Patel, K., & Cuellari, R.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-08-11
- Volume
- 114
- Issue
- 35
- Pages
- 14915-14921
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2077287184
- Cited by
- 248
- References
- 1
- FWCI
- 21.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Selective Dopamine Biosensor Fabricated with Silanized Graphene. https://app.cochat.ai/papers/10.1021/jp1020593
- The paper
- Hou, S., Kasner, M. L., Su, S., Patel, K., & Cuellari, R. (2010). Highly Sensitive and Selective Dopamine Biosensor Fabricated with Silanized Graphene. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp1020593
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.