Monolayer-Capped Cubic Platinum Nanoparticles for Sensing Nonpolar Analytes in Highly Humid Atmospheres
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We report on the feasibility of cubic Pt nanoparticles (NPs) capped with four representative organic ligands, viz. oleylamine (ODA), 11-mercaptoundecanol, 11-mercaptoundecanoic acid, and benzylmercaptan, for sensing gaseous nonpolar analytes in humid atmospheres. Chemiresistors based on cubic Pt NPs with nonpolar ligands show a very large increase in resistance upon exposure to nonpolar analyte vapors, combined with a low sensitivity to polar analyte vapors, especially to water. The sensing mechanism can be understood in terms of analyte-induced changes in the NP−NP core distance and changes in the permittivity of the medium between the NPs. The sensing capabilities of the Pt NP chemiresistors for nonpolar molecules in highly humid atmospheres are demonstrated by dosing an ODA-capped cubic Pt NP sensor with air mixtures containing low octane concentrations and high humidity levels that are typical for many applications. The simple construction, low cost, stability, fast response, and high sensitivity to nonpolar molecules, together with the low sensitivity to water vapor, are promising features for sensing applications in real confounding atmospheres.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation, Self-Assembly, and Mechanistic Study of Highly Monodispersed Nanocubes
Ren, J., & Tilley, R. D. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067636w · Cited by 227
Cited by
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Self-citationNakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citationGas Sensors Based on Chemi-Resistive Hybrid Functional Nanomaterials
Jian, Y., Hu, W., Zhao, Z., Cheng, P., Haick, H., Yao, M., & Wu, W. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-0407-5 · Cited by 429
Self-citationLi, G., Cheng, Z., Xiang, Q., Yan, L., Wang, X., & Xu, J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.09.117 · Cited by 422
Metadata
- Authors
- Dovgolevsky, E., Konvalina, G., Tisch, U., & Haick, H.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-07-30
- Volume
- 114
- Issue
- 33
- Pages
- 14042-14049
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2046965597
- Cited by
- 75
- References
- 1
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.