The DOI matches its Crossref record.
Thermal Behavior of Ionic Liquids Containing the FSI Anion and the Li+ Cation
Abstract
Ionic liquids (ILs) containing the bis(fluorosulfonyl)imide ([(FSO 2 ) 2 N] −, “FSI”) anion have been attracting growing interest as electrolytes in lithium (ion) batteries because in many instances they offer the best liquid properties. At the same time, though, there have been reports that some examples can undergo highly exothermic reactions under certain conditions. As this behavior could potentially rule out their use in batteries, we present here a study of the thermal stability of a series of lithium battery IL electrolytes that contain the FSI anion. When the ionic liquid N -methyl- N -propyl pyrrolidinium bis(fluorosulfonyl)imide (C 3 mpyrFSI) is mixed with either LiFSI or lithium bis(trifluoromethanesulfonyl)imide (LiTFSI), an exothermic reaction occurs at ∼120 °C. This reaction is related to the copresence of the Li + and FSI ions and involves a trace amount of water. The exothermic decomposition is also observed when wet LiFSI is heated. The exothermic enthalpy increases with water content (tested up to 6 wt %) and can be as high as 200 J g −1 . Infrared and Raman spectra show that the Li + cations and the FSI anions form a relatively strong association in ionic liquid media with the result that mixtures of FSI IL and LiTFSI also give rise to the exotherm. Electrochemical investigations reveal that the decomposition of FSI effectively lowers the concentration of lithium ions available. Mass spectrometric analysis strongly suggests that degradation involves reaction to form oligomers of an FSI-derived base unit under dry condition but produces smaller fragments if water is involved. Overall, the results raise concern over the safety of FSI salts as lithium battery electrolytes and at least establish a case for further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrolytes and Interphases in Li-Ion Batteries and Beyond
Xu, K. (2014) · Chemical Reviews · doi:10.1021/cr500003w · Cited by 5,566
Challenges Facing Lithium Batteries and Electrical Double‐Layer Capacitors
Choi, N., Chen, Z., Freunberger, S. A., Ji, X., Sun, Y., Amine, K., Yushin, G., Nazar, L. F., Cho, J., & Bruce, P. G. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201429 · Cited by 2,700
Pan, H., Lu, X., Yu, X., Hu, Y., Li, H., Yang, X., & Chen, L. (2013) · Advanced Energy Materials · doi:10.1002/aenm.201300139 · Cited by 516
Philippe, B., Dedryvère, R., Gorgoi, M., Rensmo, H., Gonbeau, D., & Edström, K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403082s · Cited by 343
Thermal decomposition of carboxylate ionic liquids: trends and mechanisms
Clough, M. T., Geyer, K., Hunt, P. A., Mertes, J., & Welton, T. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp53648c · Cited by 261
Metadata
- Authors
- Huang, J., & Hollenkamp, A. F.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-11-15
- Volume
- 114
- Issue
- 49
- Pages
- 21840-21847
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W1969942105
- Cited by
- 168
- References
- 0
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.