The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Double Layer Structure of Ionic Liquids at the Au(111) Electrode Interface: An Atomic Force Microscopy Investigation
Abstract
The double layer structure of two ionic liquids (ILs), 1-butyl-1-methylpyrrolidinium tris(pentafluoroethyl)trifluorophosphate ([Py 1,4 ]FAP) and 1-ethyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([EMIm]FAP) at the polarized Au(111) electrode interface is probed using Atomic Force Microscopy force measurements. The force-separation profiles suggest a multilayered morphology is present at the electrified Au(111)−IL interface, with more near surface layers detected at higher potentials. At the (slightly negative) open circuit potential, multiple ion layers are present, and the innermost layer, in contact with the Au(111) surface, is enriched in the cation due to electrostatic adsorption. Upon applying negative electrode potentials (−1.0 V, −2.0 V), stronger IL near surface structure is detected: both the number of ion layers and the force required to rupture these layers increases. Positive electrode potentials (+1.0 V, +2.0 V) also enhance IL near surface structure, but not as much as negative potentials, because surface-adsorbed anions are less effective at templating structure in subsequent layers than cations. This interfacial structure is not consistent with a double layer in the Stern−Gouy−Chapman sense, as there is no diffuse layer. The structure is consistent with a capicitative double-layer model, with a very small separation distance between the planes of charge.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
Cited by
Structure and Nanostructure in Ionic Liquids
Hayes, R., Warr, G. G., & Atkin, R. (2015) · Chemical Reviews · doi:10.1021/cr500411q · Cited by 2,293
Self-citationMultiscale Studies on Ionic Liquids
Dong, K., Liu, X., Dong, H., Zhang, X., & Zhang, S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00776 · Cited by 773
Long range electrostatic forces in ionic liquids
Gebbie, M. A., Smith, A. M., Dobbs, H. A., Lee, A. A., Warr, G. G., Banquy, X., Valtiner, M., Rutland, M. W., Israelachvili, J. N., Perkin, S., et al. (2017) · Chemical Communications · doi:10.1039/c6cc08820a · Cited by 382
Self-citationIonic liquids confined in porous matrices: Physicochemical properties and applications
Singh, M. P., Singh, R. K., & Chandra, S. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2014.03.001 · Cited by 318
Electrostatic Screening Length in Concentrated Salt Solutions
Gaddam, P., & Ducker, W. (2019) · Langmuir · doi:10.1021/acs.langmuir.9b00375 · Cited by 95
Metadata
- Authors
- Hayes, R., Borisenko, N., Tam, M. K., Howlett, P. C., Endres, F., & Atkin, R.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-03-17
- Volume
- 115
- Issue
- 14
- Pages
- 6855-6863
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2042323435
- Cited by
- 370
- References
- 1
- FWCI
- 13.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.