The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Parameter Space of Graphene Chemical Vapor Deposition on Polycrystalline Cu
Open accessAbstract
A systematic study of the parameter space of graphene chemical vapor deposition (CVD) on polycrystalline Cu foils is presented, aiming at a more fundamental process rationale in particular regarding the choice of carbon precursor and mitigation of Cu sublimation. CH 4 as precursor requires H 2 dilution and temperatures ≥1000 °C to keep the Cu surface reduced and yield a high-quality, complete monolayer graphene coverage. The H 2 atmosphere etches as-grown graphene; hence, maintaining a balanced CH 4 /H 2 ratio is critical. Such balance is more easily achieved at low-pressure conditions, at which however Cu sublimation reaches deleterious levels. In contrast, C 6 H 6 as precursor requires no reactive diluent and consistently gives similar graphene quality at 100–150 °C lower temperatures. The lower process temperature and more robust processing conditions allow the problem of Cu sublimation to be effectively addressed. Graphene formation is not inherently self-limited to a monolayer for any of the precursors. Rather, the higher the supplied carbon chemical potential, the higher the likelihood of film inhomogeneity and primary and secondary multilayer graphene nucleation. For the latter, domain boundaries of the inherently polycrystalline CVD graphene offer pathways for a continued carbon supply to the catalyst. Graphene formation is significantly affected by the Cu crystallography; i.e., the evolution of microstructure and texture of the catalyst template form an integral part of the CVD process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In situ Observations of Catalyst Dynamics during Surface-Bound Carbon Nanotube Nucleation
Hofmann, S., Sharma, R., Ducati, C., Du, G., Mattevi, C., Cepek, C., Cantoro, M., Pisana, S., Parvez, A., Cervantes-Sodi, F., et al. (2007) · Nano Letters · doi:10.1021/nl0624824 · Cited by 736
Self-citation
Cited by
Wang, L., Boutilier, M. S. H., Kidambi, P. R., Jang, D., Hadjiconstantinou, N. G., & Karnik, R. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.72 · Cited by 824
Self-citationChemical Vapour Deposition of Graphene—Synthesis, Characterisation, and Applications: A Review
Saeed, M., Alshammari, Y., Majeed, S. A., & Al-Nasrallah, E. (2020) · Molecules · doi:10.3390/molecules25173856 · Cited by 459
Kidambi, P. R., Bayer, B. C., Blume, R., Wang, Z.-J., Baehtz, C., Weatherup, R. S., Willinger, M.-G., Schloegl, R., & Hofmann, S. (2013) · Nano Letters · doi:10.1021/nl4023572 · Cited by 264
Self-citation
Metadata
- Authors
- Kidambi, P. R., Ducati, C., Dlubak, B., Gardiner, D., Weatherup, R. S., Martin, M.-B., Seneor, P., Coles, H., & Hofmann, S.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-10-12
- Volume
- 116
- Issue
- 42
- Pages
- 22492-22501
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2169572995
- Cited by
- 175
- References
- 1
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.