The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Fe3O4@Carbon Microsphere Supported Ag–Au Bimetallic Nanocrystals with the Enhanced Catalytic Activity and Selectivity for the Reduction of Nitroaromatic Compounds
Abstract
The heterostructure Ag–Au bimetallic nanocrystals supported on Fe 3 O 4 @carbon composite microspheres were synthesized by one facile and controllable approach, wherein the Ag nanocrystals attached on the Fe 3 O 4 @carbon microspheres were prepared first and served as reductant for the galvanic replacement reaction with the Au precursor (HAuCl 4 ). Upon varying the feeding amounts of the Au precursor, the bimetallic compositions on the Fe 3 O 4 @carbon microsphere could be readily tuned resulting in a series of composite microspheres with different Au-to-Ag molar ratios. Subsequently, we thus investigated the catalytic activity and selectivity of the magnetic composite catalysts from two sides. First, 4-nitrophenol (4-NP) was applied as a model molecule to study the effect of different Au-to-Ag molar ratios on catalytic capabilities of the resulting composite microspheres. It was found that upon the addition of NaBH 4 the catalytic capability was markedly enhanced when the Au content was increased. The maximum activity parameter value reached 1580 s –1 g –1, which is far higher than those of known monometallic composites. Also, they could give the equally high yields for other nitroaromatic compounds with various substituents, irrespective of the linked electron-donating or electron-withdrawing groups. Second, the synergistic effects of the carbon substrate in the catalysis reaction were demonstrated. When compared with colloidal SiO 2, TiO 2, and poly(styrene- co -acrylic acid) substrates, the carbon support not only facilitated the enhancement of the catalytic performance of the noble metal nanocrystals but was also more suitable for the in situ preparation of Au–Ag bimetallic nanocrystals using the GRR. Besides, the particles’ convenience in terms of their magnetic separability and outstanding reusability was validated through many successive reduction reaction cycles. In light of these unique characteristics, the Fe 3 O 4 @C@Ag–Au composite microspheres show promising and great potential for practical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Nanoalloys: From Theory to Applications of Alloy Clusters and Nanoparticles
Ferrando, R., Jellinek, J., & Johnston, R. L. (2008) · Chemical Reviews · doi:10.1021/cr040090g · Cited by 3,690
Xu, D., Liu, Z., Yang, H., Liu, Q., Zhang, J., Fang, J., Zou, S., & Sun, K. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200900293 · Cited by 385
Cited by
Baruah, B., Gabriel, G. J., Akbashev, M. J., & Booher, M. E. (2013) · Langmuir · doi:10.1021/la305068p · Cited by 391
Metadata
- Authors
- An, Q., Yu, M., Zhang, Y., Ma, W., Guo, J., & Wang, C.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-10-10
- Volume
- 116
- Issue
- 42
- Pages
- 22432-22440
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2000361873
- Cited by
- 190
- References
- 3
- FWCI
- 8.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.