Cited by 42Advanced Memory and Neural ComputingConducting polymers and applicationsElectrochemical sensors and biosensors

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Electrochemical System with Memimpedance Properties

MacVittie, Kevin, Katz, Evgeny·2013·The Journal of Physical Chemistry C

Abstract

An electrochemical system based on a pH-switchable polymer-modified electrode was designed to demonstrate memory properties. The pH changes in the system were produced electrochemically in situ upon electrochemical reduction or oxidation of H 2 O 2 . Depending on the direction of the current, different pH changes were achieved and the modified electrode was switched between higher or lower resistance and capacitance. In the absence of the current the electrode preserved the last resistance and capacitance values, thus demonstrating properties of memristor and memcapacitor simultaneously (memimpedance). The switchable interface between the modified electrode and solution potentially allows functional integration between the electrochemical memimpedance device and biomolecular systems processing chemical signals.

Overview

Integrity signals

Registry

Crossref · 10.1021/jp409257v

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 4 references

Research works printed but not linked: 33

  1. Calude C. S., 2009, Unconventional Computation. Lecture Notes in Computer Science, 5715
  2. de Murieta I. S., 2011, Curr. Bioinformatics, 6, 173, 10.2174/1574893611106020173 · DOI
  3. Katz E., 2012, Molecular and Supramolecular Information Processing: From Molecular Switches to Unconventional Computing, 10.1002/9783527645442 · DOI
  4. De Silva A. P., 2007, Coord. Chem. Rev., 251, 1623, 10.1016/j.ccr.2007.03.001 · DOI
  5. Szacilowski K., 2008, Chem. Rev., 108, 3481, 10.1021/cr068403q · DOI
  6. Katz E., 2012, Biomolecular Computing: From Logic Systems to Smart Sensors and Actuators
  7. Shapiro E., 2007, Nat. Nanotechnol., 2, 84, 10.1038/nnano.2007.23 · DOI
  8. Benenson Y., 2009, Mol. Biosyst., 5, 675, 10.1039/b902484k · DOI
  9. Andreasson J., 2010, Chem. Soc. Rev., 39, 174, 10.1039/B820280J · DOI
  10. Katz E., 2010, Chem. Soc. Rev., 39, 1835, 10.1039/b806038j · DOI
  11. Pischel U., 2008, New J. Chem., 32, 395, 10.1039/B710216J · DOI
  12. Amelia M., 2008, Angew. Chem., Int. Ed., 47, 6240, 10.1002/anie.200802018 · DOI
  13. Arugula M. A., 2010, J. Phys. Chem. B, 114, 5222, 10.1021/jp101101b · DOI
  14. Andreasson J., 2008, J. Am. Chem. Soc., 130, 11122, 10.1021/ja802845z · DOI
  15. Zhou J., 2009, J. Phys. Chem. B, 113, 16065, 10.1021/jp9079052 · DOI
  16. Zavalov O., 2012, J. Phys. Chem. B, 116, 9683, 10.1021/jp305183d · DOI
  17. Halámek J., 2012, J. Phys. Chem. B, 116, 4457, 10.1021/jp300447w · DOI
  18. de Ruiter G., 2011, J. Mater. Chem., 21, 17575, 10.1039/c1jm12343b · DOI
  19. MacVittie K., 2012, Chem. Commun., 48, 11742, 10.1039/c2cc37075a · DOI
  20. MacVittie K., 2013, Chem. Commun., 49, 6962, 10.1039/c3cc43272f · DOI
  21. Bocharova V., 2012, J. Phys. Chem. Lett., 3, 1234, 10.1021/jz300098b · DOI
  22. Pershin Y. V., 2011, Comput. Theor. Nanosci., 8, 441, 10.1166/jctn.2011.1708 · DOI
  23. Szot K., 2011, Nanotechnology, 22, 254001, 10.1088/0957-4484/22/25/254001 · DOI
  24. Erokhin V., 2011, J. Comp. Theor. Nanosci., 8, 313, 10.1166/jctn.2011.1695 · DOI
  25. Katz E., 2012, J. Mater. Chem., 22, 8171, 10.1039/c2jm30172e · DOI
  26. Privman M., 2009, J. Am. Chem. Soc., 131, 1314, 10.1021/ja8088108 · DOI
  27. Di Ventra M., 2009, Proc. IEEE, 97, 1717, 10.1109/JPROC.2009.2021077 · DOI · Paper page
  28. Tam T. K., 2010, Electroanalysis, 22, 35, 10.1002/elan.200900442 · DOI
  29. Zhou J., 2009, ACS Appl. Mater. Interfaces, 1, 144, 10.1021/am800088d · DOI
  30. Draper J., 2004, Langmuir, 20, 4064, 10.1021/la0361316 · DOI
  31. Minko S., 2002, Langmuir, 18, 289, 10.1021/la015637q · DOI
  32. Carolus M. D., 2005, Langmuir, 21, 4236, 10.1021/la0470582 · DOI
  33. Tam T. K., 2010, Langmuir, 26, 4506, 10.1021/la903527p · DOI

Cited by

Sorted by citations

Metadata

Authors
MacVittie, K., & Katz, E.
Affiliations
Clarkson University (US)
Corresponding author
Katz, Evgeny
Venue
The Journal of Physical Chemistry C
Published
2013-11-18
Volume
117
Issue
47
Pages
24943-24947
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2331841482
Cited by
42
References
4
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 2 · 2021: 2 · 2019: 5 · 2018: 4 · 2017: 3 · 2016: 7 · 2015: 6 · 2014: 9
FWCI
4.40
Type
journal article
Language
en
Open access
closed
Locations
The Journal of Physical Chemistry C (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Memory and Neural Computing
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
Keywords
memristors, memcapacitor, polymer-modified electrodes, non-volatile memory, electrochemical devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review