The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Non-Fickian Water Vapor Sorption Dynamics by Nafion Membranes
Abstract
Dynamics of water absorption from a saturated vapor and water desorption into dry air for Nafion 1100 EW ionomers have been measured for film thicknesses between 51 and 606 microm and at temperatures ranging from 30 to 90 degrees C. Water absorption and desorption exhibit two distinct non-Fickian characteristics: (1) desorption is 10 times faster than absorption and (2) the normalized mass change does not collapse to a single master curve when plotted against time normalized by membrane thickness squared, t/l2, for either absorption or desorption. Water desorption data were fit well by a model in which diffusion is rapid and interfacial mass transport resistance is the rate-limiting process for water loss. Water absorption is described by a two-stage process. At early times, interfacial mass transport controls water absorption, and at longer times, water absorption is controlled by the dynamics of polymer swelling and relaxation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of water diffusion coefficients in perfluorosulfonate ionomeric membranes
Zawodzinski, T. A., Neeman, M., Sillerud, L. O., & Gottesfeld, S. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a060 · Cited by 987
Water sorption, desorption and transport in Nafion membranes
Majsztrik, P. W., Satterfield, M. B., Bocarsly, A. B., & Benziger, J. B. (2007) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.06.022 · Cited by 348
Self-citation
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Water transport in polymer electrolyte membrane fuel cells
Jiao, K., & Li, X. (2011) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2010.06.002 · Cited by 1,086
Ijaodola, O. S., El- Hassan, Z., Ogungbemi, E., Khatib, F. N., Wilberforce, T., Thompson, J., & Olabi, A. G. (2019) · Energy · doi:10.1016/j.energy.2019.04.074 · Cited by 461
Review on water management methods for proton exchange membrane fuel cells
Wang, X. R., Ma, Y., Gao, J., Li, T., Jiang, G. Z., & Sun, Z. Y. (2021) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2020.06.211 · Cited by 318
Diffusion and Interfacial Transport of Water in Nafion
Zhao, Q., Majsztrik, P., & Benziger, J. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp1112125 · Cited by 301
Self-citation
Metadata
- Authors
- Satterfield, M. B., & Benziger, J. B.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-03-01
- Volume
- 112
- Issue
- 12
- Pages
- 3693-3704
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2023988502
- Cited by
- 174
- References
- 2
- FWCI
- 11.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.