The DOI matches its Crossref record.
Membrane-Bound Molecular Rotors Measure Viscosity in Live Cells via Fluorescence Lifetime Imaging
Abstract
We report intracellular fluorescence lifetime imaging (FLIM) and fluorescence anisotropy measurements of two meso-substituted fluorophores based on the boron−dipyrrin (BODIPY) structure. Both dyes incorporate hydrophobic groups, which render them membrane-soluble. We have obtained values for quantum yields, radiative and nonradiative rate constants, fluorescence lifetimes, and time-resolved anisotropy data for the dyes in homogeneous methanol/glycerol solutions of varying viscosities from 0.6 to 950 cP. We find that the fluorescence lifetimes and rotational correlation times for both dyes increase with increasing viscosity, as predicted by theory. These molecules can thus serve as fluorescent molecular rotors to report on local microviscosity, including that in live cells. The dyes are readily taken up by cells as imaged using confocal fluorescence microscopy. Using FLIM, we have detected two distinct fluorescence lifetime populations for both dyes in live SK-OV-3 human ovarian carcinoma cells, corresponding to apparent viscosity values of 160 ± 20 and 260 ± 40 cP, each found in distinct intracellular domains. In both cellular domains, independent of the fluorophore used, the viscosity values significantly exceed that expected for the aqueous phase of cellular cytoplasm, suggesting slower diffusion and reaction rates in this hydrophobic microenvironment. FLIM measurements were complemented with time-resolved fluorescence anisotropy measurements, which confirm the high viscosity values in the immediate environment of both rotors. The present study highlights the power of FLIM to map heterogeneous microenvironments of complex biological systems and also the use of fluorescent molecular rotors as microviscosity sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
BODIPY-based probes for the fluorescence imaging of biomolecules in living cells
Kowada, T., Maeda, H., & Kikuchi, K. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00030k · Cited by 1,381
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Peng, X., Yang, Z., Wang, J., Fan, J., He, Y., Song, F., Wang, B., Sun, S., Qu, J., Qi, J., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1104014 · Cited by 431
Metadata
- Authors
- Levitt, J. A., Kuimova, M. K., Yahioglu, G., Chung, P.-H., Suhling, K., & Phillips, D.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-04-24
- Volume
- 113
- Issue
- 27
- Pages
- 11634-11642
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W1989414372
- Cited by
- 249
- References
- 0
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Membrane-Bound Molecular Rotors Measure Viscosity in Live Cells via Fluorescence Lifetime Imaging. https://app.cochat.ai/papers/10.1021/jp9013493
- The paper
- Levitt, J. A., Kuimova, M. K., Yahioglu, G., Chung, P.-H., Suhling, K., & Phillips, D. (2009). Membrane-Bound Molecular Rotors Measure Viscosity in Live Cells via Fluorescence Lifetime Imaging. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp9013493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.