Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 249

The DOI matches its Crossref record.

Membrane-Bound Molecular Rotors Measure Viscosity in Live Cells via Fluorescence Lifetime Imaging

Levitt, James A., Kuimova, Marina K., Yahioglu, Gokhan, Chung, Pei-Hua, Suhling, Klaus, Phillips, David·2009·The Journal of Physical Chemistry C

Abstract

We report intracellular fluorescence lifetime imaging (FLIM) and fluorescence anisotropy measurements of two meso-substituted fluorophores based on the boron−dipyrrin (BODIPY) structure. Both dyes incorporate hydrophobic groups, which render them membrane-soluble. We have obtained values for quantum yields, radiative and nonradiative rate constants, fluorescence lifetimes, and time-resolved anisotropy data for the dyes in homogeneous methanol/glycerol solutions of varying viscosities from 0.6 to 950 cP. We find that the fluorescence lifetimes and rotational correlation times for both dyes increase with increasing viscosity, as predicted by theory. These molecules can thus serve as fluorescent molecular rotors to report on local microviscosity, including that in live cells. The dyes are readily taken up by cells as imaged using confocal fluorescence microscopy. Using FLIM, we have detected two distinct fluorescence lifetime populations for both dyes in live SK-OV-3 human ovarian carcinoma cells, corresponding to apparent viscosity values of 160 ± 20 and 260 ± 40 cP, each found in distinct intracellular domains. In both cellular domains, independent of the fluorophore used, the viscosity values significantly exceed that expected for the aqueous phase of cellular cytoplasm, suggesting slower diffusion and reaction rates in this hydrophobic microenvironment. FLIM measurements were complemented with time-resolved fluorescence anisotropy measurements, which confirm the high viscosity values in the immediate environment of both rotors. The present study highlights the power of FLIM to map heterogeneous microenvironments of complex biological systems and also the use of fluorescent molecular rotors as microviscosity sensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp9013493

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 249

Metadata

Authors
Levitt, J. A., Kuimova, M. K., Yahioglu, G., Chung, P.-H., Suhling, K., & Phillips, D.
Venue
The Journal of Physical Chemistry C
Published
2009-04-24
Volume
113
Issue
27
Pages
11634-11642
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W1989414372
Cited by
249
References
0
FWCI
5.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Membrane-Bound Molecular Rotors Measure Viscosity in Live Cells via Fluorescence Lifetime Imaging. https://app.cochat.ai/papers/10.1021/jp9013493
The paper
Levitt, J. A., Kuimova, M. K., Yahioglu, G., Chung, P.-H., Suhling, K., & Phillips, D. (2009). Membrane-Bound Molecular Rotors Measure Viscosity in Live Cells via Fluorescence Lifetime Imaging. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp9013493

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.