Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 333

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Photogeneration and Ultrafast Dynamics of Excitons and Charges in P3HT/PCBM Blends

Open access
Piris, Jorge, Dykstra, Tieneke E., Bakulin, Artem A., Loosdrecht, Paul H.M. van, Knulst, Walter, Trinh, M. Tuan, Schins, Juleon M., Siebbeles, Laurens D.A.·2009·The Journal of Physical Chemistry C

Abstract

The photogeneration quantum yield and dynamics of charge carriers and excitons in thin films of neat regioregular poly(3-hexylthiophene) (P3HT) and blends with [6,6]-phenyl-C 61 -butyric acid methyl ester (PCBM) were studied with ultrafast optical pump−probe spectroscopy. In neat P3HT the quantum yield for direct photogeneration of charge carriers amounts to 0.15 per absorbed photon. The remaining fraction of absorbed photons leads to formation of excitons. Recombination of charges reduces the quantum yield to about 25% of its initial value on a time scale of 100 ps followed by decay to a no longer observable yield after 1 ns. Addition of 50% PCBM by weight leads to ultrafast (<200 fs) formation of charge pairs with a total quantum yield of 0.5. The presence of 50% PCBM causes exciton decay to be about an order of magnitude faster than in neat P3HT, which is expected to be at least in part due to interfacial exciton dissociation into charge carriers. The yield of charges in the blend has decayed to about half its initial value after 100 ps, while no further decay is observed within 1 ns. The small fraction (∼1%) of excitons in neat P3HT that is probed by photoluminescence measurements has a lifetime of 660 ps, which significantly exceeds the 200 ps lifetime of nonfluorescent excitons that are probed by transient absorption measurements. The nonfluorescent excitons have a diffusion coefficient of about 2 × 10 −4 cm 2 /s, which is an order of magnitude smaller than reported values for fluorescent excitons. The interaction radius for second-order decay of photoexcitations is as large as 8−17 nm, in agreement with an earlier result in the literature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp904229q

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 333

Metadata

Authors
Piris, J., Dykstra, T. E., Bakulin, A. A., Loosdrecht, P. H. M. V., Knulst, W., Trinh, M. T., Schins, J. M., & Siebbeles, L. D. A.
Venue
The Journal of Physical Chemistry C
Published
2009-07-13
Volume
113
Issue
32
Pages
14500-14506
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2004744623
Cited by
333
References
1
FWCI
25.87
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.