The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
X-ray Attenuation Property of Dendrimer-Entrapped Gold Nanoparticles
Abstract
We report the X-ray attenuation property of dendrimer-entrapped gold nanoparticles (Au DENPs) that could be used as a computed tomography (CT) contrast agent. Amine-terminated generation 5 (G5.NH 2 ) poly(amidoamine) dendrimers were used as templates to complex AuCl 4 − ions for subsequent reductive formation of Au DENPs using sodium borohydride as a reducing agent. By varying the molar ratio between gold salt to G5.NH 2, Au DENPs with a size range of 2−4 nm can be prepared. The formed Au DENPs are not only stable in water, PBS buffer, and cell culture media but also at different temperatures (from 4 to 50 °C) and different pH conditions (pH 5−8). X-ray absorption coefficient measurements show that the attenuation of Au DENPs is much higher than that of the iodine-based contrast agent at the same molar concentration of the active element (Au versus iodine). Furthermore, CT scanning showed significant enhancement at the point of mice injected subcutaneously with Au DENPs, and intravenous injection of acetylated Au DENPs enabled the X-ray CT imaging of mice, rendering them a promising contrast agent in CT imaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PATRI, A., KUKOWSKALATALLO, J., & BAKERJR, J. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.09.014 · Cited by 597
Cited by
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Nanoparticles as contrast agents for in-vivo bioimaging: current status and future perspectives
Hahn, M. A., Singh, A. K., Sharma, P., Brown, S. C., & Moudgil, B. M. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4207-5 · Cited by 485
Li, J., Hu, Y., Yang, J., Wei, P., Sun, W., Shen, M., Zhang, G., & Shi, X. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.065 · Cited by 394
Self-citationPeng, C., Zheng, L., Chen, Q., Shen, M., Guo, R., Wang, H., Cao, X., Zhang, G., & Shi, X. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.052 · Cited by 391
Self-citationNanoparticle contrast agents for computed tomography: a focus on micelles
Cormode, D. P., Naha, P. C., & Fayad, Z. A. (2014) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1551 · Cited by 362
Metadata
- Authors
- Guo, R., Wang, H., Peng, C., Shen, M., Pan, M., Cao, X., Zhang, G., & Shi, X.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-12-15
- Volume
- 114
- Issue
- 1
- Pages
- 50-56
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2055128693
- Cited by
- 166
- References
- 1
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray Attenuation Property of Dendrimer-Entrapped Gold Nanoparticles. https://app.cochat.ai/papers/10.1021/jp9078986
- The paper
- Guo, R., Wang, H., Peng, C., Shen, M., Pan, M., Cao, X., Zhang, G., & Shi, X. (2010). X-ray Attenuation Property of Dendrimer-Entrapped Gold Nanoparticles. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp9078986
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.