The DOI matches its Crossref record.
Preparation and Recognition Properties of Bovine Hemoglobin Magnetic Molecularly Imprinted Polymers
Abstract
A simple method for the preparation of core-shell micro/nanostructured magnetic molecularly imprinted polymers (MIPs) for protein recognition is described. Magnetic MIPs were synthesized by copolymering gamma-aminopropyltrimethoxysilane and tetraethyl orthosilicate at the surface of Fe(3)O(4) nanospheres, which were directly covalently bound with template molecule, bovine hemoglobin (BHb), through imine bond. Transmission electron microscopy and scanning electron microscopy images showed that the Fe(3)O(4) nanospheres with diameter about 50-150 nm were coated with the MIPs layer with average thickness about 10 nm, which enabled the magnetic MIPs to have a sensitive and fast magnetic response. The proximity between the thickness of MIPs layer and the spatial size of BHb indicated that the imprinted sites almost situated at the surface of magnetic MIPs, leading a rapid adsorption saturation within 1 h. And the adsorption amounts of magnetic MIPs toward BHb were estimated to be 10.52 mg/g at pH 6.5, which was 4.6 times higher than that of magnetic nonmolecularly imprinted polymers. Meanwhile, the result of selective test showed that the magnetic MIPs had an excellent recognition capacity to BHb compared to the other nontemplate proteins. Except for the spatial size complementary between BHb and the binding sites in magnetic MIPs, the electrostatic interaction also was proven to be an important factor for recognizing the imprinting molecule.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular imprinting: perspectives and applications
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00061d · Cited by 2,460
The rational development of molecularly imprinted polymer-based sensors for protein detection
Whitcombe, M. J., Chianella, I., Larcombe, L., Piletsky, S. A., Noble, J., Porter, R., & Horgan, A. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00049c · Cited by 711
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Zhang, M., Zhang, X., He, X., Chen, L., & Zhang, Y. (2012) · Nanoscale · doi:10.1039/c2nr30316g · Cited by 302
Magnetic separation techniques in sample preparation for biological analysis: A review
He, J., Huang, M., Wang, D., Zhang, Z., & Li, G. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.04.017 · Cited by 275
Application of functionalized magnetic nanoparticles in sample preparation
Xie, L., Jiang, R., Zhu, F., Liu, H., & Ouyang, G. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7302-6 · Cited by 266
Lv, Y., Tan, T., & Svec, F. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.02.005 · Cited by 252
Synthesis and applications of functionalized magnetic materials in sample preparation
Li, X.-S., Zhu, G.-T., Luo, Y.-B., Yuan, B.-F., & Feng, Y.-Q. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.10.015 · Cited by 252
Xu, K., Wang, Y., Wei, X., Chen, J., Xu, P., & Zhou, Y. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2707-8 · Cited by 84
Metadata
- Authors
- Kan, X., Zhao, Q., Shao, D., Geng, Z., Wang, Z., & Zhu, J.-J.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-02-25
- Volume
- 114
- Issue
- 11
- Pages
- 3999-4004
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2057327906
- Cited by
- 183
- References
- 0
- FWCI
- 20.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.